18 - TROUBLE SHOOTING
10
11
THE RED ERROR (ERR) LED TURNS ON, AND THE CONTROL UNIT DOES NOT FUNCTION
- Repeat Automatic Gate Travel Learning – see section 9
-The control unit is in Safety Test mode (section 14) to deactivate:
- Faulty control unit – replace the unit
- Memory hybrid fault - replace the board
GATE DOES NOT MOVE AT ALL
- check that the control box has power.
- Check the main fuse. IMPORTANT: TURN OFF POWER BEFORE CHECKING THIS FUSE
- Verify that the STOP (ST) LED is on. If not check connection on the STOP input (terminal 14).
This is a Normally Closed contact.
- Check that the remote control is programmed for the system (Section 5)
GATE OPEN BUT NOT CLOSE
- Check that the photo sensors are properly connected (PHO LED is on). If the LED is off ensure that
the photo-sensors are connected properly and that nothing is blocking the beam’s path.
- Check that the green START LED is off. If it is on then check connection to the START input (terminal 12).
This is a Normally Open contact.
- Check photo red LED to be on, if not check the link (jumper) or the photo 2 connection
THE REMOTE CONTROL DOES NOT WORK
- Check that the LED on the remote is working. If not replace the remote’s batteries.
- Check that the red RADIO LED briefly flashes when the remote transmits. If it does not then
re-program the remote.
GATE CLOSES BY ITSELF (WITHOUT THE REMOTE BEING PRESSED)
- Check the operation mode – DipSwitches 2 ON , DipSwitch 3 OFF >> Step-By-Step mode
- Check that DipSwitch 7 (Close after Photo) is OFF.
GATE STOPS HALFWAY AND THEN MOVES IN THE OPPOSITE DIRECTION
- The obstacle sensitivity is too low: Increase the Obstacle Sensitivity Potentiometer.
- Check that the gate does not cut the photo sensor beam when moving.
- Open the manual override and check that the gate travels freely all the way.
- repeat Automatic Gate Travel learning (section 9)
GATE STOPS HALFWAY
- Not enough force; Increase the POWER potentiometer. Adjustment to this potentiometer will also
change the speed and will require repeating the Automatic Gate Travel Learning (Section 9).
- The gate stops after they reach the slow down point. Manually set (or remove the slow down)
points (Section 10).
SHORT RECEPTION RANGE
- The remote control batteries are weak or dead. Replace batteries.
- An external antenna needs to be added to the system.
NOTE: External interferences from power lines and other emitting devices can influence the
reception range. Installing an external antenna may improve the reception range.
G
ATE IS NOT TIGHTLY CLOSED WHEN REACHING THE CLOSED POSITION
- Increase the Obstacle Sensitivity potentiometer so that the wings are pressing harder against the stopper.
- Check that all brackets and hinges are secure and that their bolts are tightened
THE MANUAL RELEASE IS JAMMED
- The override mechanism is too tight. Decrease the Obstacle Sensitivity potentiometer.
- It is recommended to repeat the Automatic Gate Travel Learning after adjustment to this potentiometer
Содержание Star 224
Страница 11: ...11...