background image

12

EN

5.

 Maintenance

The automation must be subjected to maintenance work on a regular 
basis in order to guarantee it lasts.

 

CAUTION! - The maintenance operations must be per-

formed in strict compliance with the safety directions provid-
ed in this manual and according to the applicable legislation 
and standards.

If other devices are present, follow the directions provided in the cor-
responding maintenance schedule.

01. 

OVO requires scheduled maintenance work every 6 months or 

3,000 manoeuvres after previous maintenance.

02. 

Disconnect any source of electric power.

03. 

Check for any deterioration in automation system components, 

paying special attention to erosion or oxidation of the structural parts. 
Replace any parts which are below the required standard.

04. 

Check the wear and tear on the moving parts: belt, carriage, pin-

ions and the door components; replace them if necessary.

05. 

Connect the electric power sources up again, and carry out all 

the tests and checks described in section 4.1 (“Testing”).

6.

 Disposal of the 

product

This product constitutes an integral part of the automation system, 
therefore it must be disposed of along with the latter.
Likewise for installation operations, when the product reaches its 
end-of-life, decommissioning operations must be performed by 

qualified personnel.

This product is made up of different types of material, some of which 
can be recycled while others must be disposed of. Seek information 
on the recycling and disposal systems available in your area for this 
product category.

 

CAUTION!

 

- Some parts of the product may contain pol-

lutants or hazardous substances that could cause serious 
damage to the environment or human health if released into 
the environment.

As indicated by the adjacent symbol, it is strictly forbid-
den to dispose of this product together with domestic 
waste. Therefore, implement separate waste collec-
tion criteria for disposal according to the regulations in 
force in your area, or return the product to the dealer 
when purchasing a new equivalent version.

 

CAUTION! - Local legislation may include the application 

of serious fines in the event of improper disposal of this prod

-

uct.

6.1 - 

Disposal of the buffer battery 

(if present)

 

CAUTION!

 The empty battery will contain toxic substances 

and must not be thrown out with ordinary rubbish. 
It should be disposed of according to the "separate" refuse collection 
procedures in effect in your local area. 

7.

 Additional    

information

7.1 - 

Programming keys

The OVO control unit is fitted with 3 keys which can be used both for 

the control of the unit during testing and the programming procedure:

P1

Within the first 10 seconds after power-up, perform 
the "RADIO" function to memorise or delete the radio 
transmitters used with OVO.
After this time interval, the key is no longer used.

P2

The 

P2

 key stops the manoeuvre; if pressed for more than 

5 seconds, it enables programming mode as described 
below.

P3

The 

P3

 key enables you to control door opening and 

closing or scroll through the programming steps.

P3

P1

P2

7.2 - 

Programming

The OVO control unit is equipped with a number of programmable 

functions; function settings are entered using 2 keys on the control 

unit: 

P3

 and 

P2

. They are displayed by means of 3 LEDs: 

L1

L2

 

and 

L3

.

There are two types of programming:

Programming on power-up:

 this type of programming can only 

be performed immediately after switching on OVO. Press and hold 

P2

 during power-up of the control unit to activate this programming 

mode.

Standard programming:

 this programming mode can be used at 

any time and is activated by pressing and holding 

P2

.

For both modes, the programming and programmable functions 
available are divided into 2 levels:

Level 1:

 functions settable in ON-OFF mode (enabled or disabled). In 

this case, the 

L1

L2

 and 

L3

 LEDS indicate a function: if lit, the func-

tion is enabled; if off, the function is disabled. See Tables 9 and 10.

Level 2:

 parameters settable on a scale of values (from 1 to 3). In 

this case, each LED (

L1

L2

 and 

L3

) indicates 1 of the 3 possible set 

values. See Tables 11 and 12.

Содержание OVO550

Страница 1: ...enze per l installazione e l uso EN Instructions and warnings for installation and use FR Consignes et avertissements pour l installation et l utilisation ES Instrucciones y advertencias para la instalación y el uso Made in Italy ...

Страница 2: ...apabilities or who lack experience and knowledge unless they have been given supervi sion or instruction concerning the use of the product by a person responsible for their safety The product is not intended as an intruder protection system Ad ditional devices must be installed alongside the automation system to guarantee effective protection Do not allow children to play with the fixed control de...

Страница 3: ...able 3 Limits in relation to force required to move door leaf Force required to move leaf N Cycle reduction percentage Up to 200 100 200 300 70 300 400 25 The height of the door enables the maximum number of cycles per hour and consecutive cycles to be calculated while the force required to move the door enables the percentage of cycle reduction to be determined for example if the leaf height is 2...

Страница 4: ...3 EN 1 a e c d b b ...

Страница 5: ... and cause malfunc tions fire or dangerous situations If the door includes an access door make sure that it does not obstruct normal travel Fit a suitable interlock system if necessary Only insert the OVO plug into sockets equipped with a safety grounding system The socket must be protected by suitable magneto thermal and differential switches 3 2 Fitting OVO Installation of the OVO gearmotor comp...

Страница 6: ...5 EN 6 1 2 3 4 4a 4b 4c 7 B 5 A 12 A 10 11 E E 9 B D 8 D C 13 F ...

Страница 7: ...tion and secure using two screws plugs or rivets according to the installation surface 03 Secure the brackets H using the screws I and nuts L select ing the hole most suited to ensure distance B as shown in fig 16 16 H L I B 0 400 mm 04 Using a ladder lift the gearmotor until the brackets are touching the ceiling Trace the drilling points and then return the gearmotor to the ground 05 Drill at the...

Страница 8: ...ord can be pulled below a height of 1 8 m 23 Q R 3 3 Installation of other devices If other devices are needed install them following the directions pro vided in the corresponding instructions Check the devices which can be connected to OVO in fig 1 and in section 3 5 Description of electrical connections 3 4 Electrical connections 01 Open the cover by loosening the screw fig 24 and pushing the bu...

Страница 9: ...ormally Open or constant resistance devices can be connected up using special procedures on the input Please refer to section 7 3 1 STOP Input for further information about STOP 3 7 Photo input for safety devices such as photocells They cut in during closure reversing the manoeuvre Normally closed contacts can be connected Further PHOTO information can be found in section 7 3 2 Photocells 6 8 Phot...

Страница 10: ...t these manoeuvres are not interrupt ed e g by a STOP command If this occurs the recognition process described in point 01 must be repeated The recognition stage of the positions and of the STOP and PHOTO input configuration can be repeated again at any time even after the installation for example if one of the mechanical stops is removed just repeat the procedure starting from step 01 30 P3 P1 P2...

Страница 11: ...tep by step command 2 Partial opening command 3 Open command 4 Close command Examples of Mode II memorisation 1st example of Mode II memorisation T1 Key Open command Automation A T2 Key Close command Automation A T3 Key Partial opening command Automation A T4 Key Partial opening command Automation A 2nd example of Mode II memorisation T1 Key Open command Automation A T2 Key Close command Automatio...

Страница 12: ...e confirming that the control unit has recognised this 07 To check the photocells and make sure that there is no interfer ence with other devices pass a 5 cm diameter 30 cm long cylin der on the optical axis first near TX then near RX and finally at the mid point between them and make sure that in all these cases the device is triggered switching from the active to the alarm status and vice versa ...

Страница 13: ...regulations in force in your area or return the product to the dealer when purchasing a new equivalent version CAUTION Local legislation may include the application of serious fines in the event of improper disposal of this prod uct 6 1 Disposal of the buffer battery if present CAUTION The empty battery will contain toxic substances and must not be thrown out with ordinary rubbish It should be dis...

Страница 14: ...of the door after a programmed pause the default Pause Time is set at 30 seconds but may be changed to 15 or 60 seconds The factory setting is semiautomatic as Automatic closure is disabled L3 LED off During normal operation of OVO the L1 L2 and L3 LEDs are lit or off depending on the status of the associated function in Standard programming mode For example L3 is lit if the Automatic closure func...

Страница 15: ...ystem and damage the leaf If the Motor force control is used in support of the system for impact force reduction the force measurement procedure must be performed after each adjustment as envisaged by standard EN 12445 Wear and atmospheric conditions influence movement of the gate force settings should be checked periodically 7 2 4 Level 2 programming adjustable parameters By default level 1 funct...

Страница 16: ...ral devices with a constant resistance of 8 2 KΩ can be cas cade connected with a single terminating resistance of 8 2 KΩ It is possible to combine two NO and NC contacts placing them in parallel taking care to place a resistance of 8 2 KΩ in series with the NC contact this also enables the combination of 3 devices NO NC and 8 2 KΩ If the STOP input is used for connecting devices with safety func ...

Страница 17: ...vation The output cannot control the electric lock directly only loads of 24Vac 2W The output must be interfaced with a relay as shown in fig 44 44 7 4 Special functions 7 4 1 Always open function The Always open function is a control unit feature which enables the user to control an opening manoeuvre when the Step by step command lasts longer than 3 seconds This is useful for connecting a timer c...

Страница 18: ...r there are any obstacles if necessary increase the force 8 1 Diagnostics and signals A few devices give out special signals that allow you to recognise the operating status or possible malfunctions 8 1 1 Flashing light and courtesy light signals During the manoeuvre the flashing light flashes once every second if connected When something is wrong the flashes are more frequent the light flashes tw...

Страница 19: ...Cause Action Off Activation of the STOP input Check the devices connected to the STOP input On Everything OK STOP Input active Table 16 LEDs on the control unit keys L1 LED Description Off Correct during normal functioning On Indicates that a radio code that is not in the memory has been received during normal functioning It flashes Function programming in progress Memorising or deleting the radio...

Страница 20: ...ctional or overhead doors which remain within the dimensions stated in table 1 and limits specified in tables 2 and 3 OVO power supply 230Vac 10 50 60Hz Max absorbed power 200 W Insulation class 1 a safety grounding system is required Emergency power supply No OVO courtesy light 12 V 21 W Flashing Light Output for 1 flashing light 12 V 21 W STOP Input For normally closed or normally open contacts ...

Страница 21: ...ised standards EN 61000 6 2 2005 EN 61000 6 3 2007 In addition the product conforms with the following Directive on partly completed machinery Directive 2006 42 EC of the European Parliament and of the Council of 17 May 2006 on machinery and amending Directive 95 16 EC recast in accordance with the following harmonised standards It is hereby declared that the relevant technical documentation has b...

Страница 22: ...tails Dati del costruttore Manufacturer s details Timbro Stamp Azienda Company Località Address Provincia Province Recapito telefonico Tel Referente Contact person King Gates S r l Phone 39 0434 737082 Fax 39 0434 786031 info king gates com www king gates com ...

Отзывы: