background image

23

13. Technical Data

Notes:

• Subject to technical modification without prior notice.

• The device is produced under our strict quality system.
 

 • The device may not work if the temperature and voltage conditions are different 

to those defined in the specifications.

Name:

Compressor Nebuliser 

Model:

NE803

Type: 

Compressor Nebuliser 

Power Source: 

1.5Vx4AA Size Alkaline batteries or USB 5V 1A 

Operating Temperature/

Humidity: 

Storage Temperature/

Humidity:

Barometric Pressure:

Weight: 

Approx. 180g (compressor only)

Dimensions: 

Approx. 115 (W) × 77 (D) × 42 (H) mm

(

compressor only

Contents: 

a nebuliser kit, an air tube, an instruction manual, a 
compressor and a mouthpiece, a mask (masks)
(option).

Operating time: 
Built-in timer:       

15min.ON-40 min.OFF.

+5°C to +40°C/15% to 90% RH

-25°C to +35°C at a relative humidity up to 90%, 
non-condensing;
>35°C to 70°C at a water vapour pressure up to 
50 hPa. 

Compressor works about 15 minutes 
once the switch is pressed and then stops.

Compressor flow: 
Compressor pressure:       

2-10 L/min

360-550mmHg

700hPa-1060hPa

Содержание NE803

Страница 1: ...r future use Please use only USB 5V 1A which complies with the standard of IEC 60601 1 which provide 2 MOPP Limit use to 15 minutes at a time and allow a 40 minutes interval before using the device ag...

Страница 2: ...liser 9 Operating instructions 8 Taking medication 14 16 7 Preparing the nebuliser for use 10 13 Care and maintenance others 9 Cleaning and daily disinfecting 17 19 9 1 17 9 2 Disinfecting the nebulis...

Страница 3: ...he device is used to nebulize 2 ml of medication twice a day for 7 5 minutes each time at room temperature 23 C Durable period may vary depending on usage environment Frequent use of the device may sh...

Страница 4: ...to be disposed of correctly at the end of the usage Please follow Local Ordinances or Regulations for disposal AUTHORISED REPRESENTATIVE IN THE EUROPEAN COMMUNITY avoided could result in death or ser...

Страница 5: ...first time after purchase if the device has not been used for a long period of time or if more than one person uses the same device Be sure to wash the nebuliser kit mouthpiece or mask after every us...

Страница 6: ...od of time more than one person uses the same device Be sure to wash or wipe the parts after use and ensure that they are thoroughly disinfected and dried and stored in a clean location Do not leave t...

Страница 7: ...r for other than necessary operation such as turning off the power while nebulising To avoid the medication residue on the face be sure to wipe the face after removing the mask Do not use a damaged ne...

Страница 8: ...hen using the device there will be some noise and vibration caused by the pump in the compressor There will also be some noise caused by the emission of compressed air from the nebuliser kit which is...

Страница 9: ...7 5 Know your device LU 7XEH PVC 100cm Nebuliser Kit Holder Power Switch Indicator Light USB Power Connector Air Filter Cover Air Filter Inside Air Tube Connector Battery Cover 21 2 9...

Страница 10: ...ection Optional parts and accessories Air tube Mask PVC Air Filter Polyester Mouthpiece PP Nebuliser Kit x1 Cap Inhalation Top Vaporiser Head Medication Tank Mouthpiece x1 Air Tube Connector Nozzle Sp...

Страница 11: ...han one week Taking Medication Notes Do not tilt the nebuliser kit so that it is at an angle of over 45 Do not crease or fold the air tube Cleaning Parts After Use Note Failure to clean the nebulising...

Страница 12: ...syringe or vial for accurate measurement of medication Warning Clean and disinfect the nebuliser kit mouthpiece or mask before using them for the first time after purchase if the device has not been...

Страница 13: ...11 7 Preparing the Nebuliser for Use 1 4 Attach the cap onto the inhalation top External USB Power Supply 9...

Страница 14: ...he cap 6 Attach the desired inhalation attachment as described below Attach the mouthpiece to the the cap 7 Attach the air tube 1 Attach the air tube to the air connector on the compressor 2 Attach th...

Страница 15: ...nectors to avoid the tube disconnecting during use Take care not to spill the medication when attaching the air tube Keep the nebuliser kit upright Use the nebuliser kit holder as a temporary holder f...

Страница 16: ...ter cover Caution Hold the nebuliser kit as indicated on the right 2 Do not cover the compressor with a blanket or towel etc during use which could result in the compressor overheating or malfunctioni...

Страница 17: ...re adviser s instructions Using the mouthpiece Put the mouthpiece in your mouth and inhale the medication breathing normally Exhale as normal through the mouthpiece Using the mask PVC Attach the mask...

Страница 18: ...ection via bacteria If there is moisture or liquid remaining in the air tube be sure to follow the procedure below to remove any moisture from within the air tube 1 Make sure that the air tube is stil...

Страница 19: ...le the nebuliser kit 4 5 6 After cleaning and disinfecting the parts rinse them thoroughly with clean water and allow the parts to air dry in a clean environment Thoroughly rinse the nebuliser kit and...

Страница 20: ...r the last treatment of the day To disinfect the parts use one of the methods described below A Use a commercially available disinfectant Follow the instructions provided by the disinfectant manufactu...

Страница 21: ...ectively When disinfecting the parts by boiling be sure to boil them in plenty of water If there is insufficient water the parts could become distorted due to the high temperature Distorted parts coul...

Страница 22: ...ubject the device or the parts to any strong shocks such as dropping the device on the floor Do not carry or leave the nebuliser while the medication tank contains medication Do not store the device i...

Страница 23: ...evice Do not operate without a filter There is no front or back orientation for the air filters Check that air filter is clean and free of dust before inserting Do not attempt to wash or clean the air...

Страница 24: ...vaporiser head missing and not assembled correctly Attach the vaporiser head correctly Is the nebuliser kit assembled correctly Assemble the nebuliser kit correctly Is the nozzle blocked Is the vapori...

Страница 25: ...ture Humidity Storage Temperature Humidity Barometric Pressure Weight Approx 180g compressor only Dimensions Approx 115 W 77 D 42 H mm compressor only Contents a nebuliser kit an air tube an instructi...

Страница 26: ...F min Appropriate Medication Quantities drug supplier s data sheet for further details Performance may vary with drugs such as suspensions or high viscosity See Independently measured according to EN...

Страница 27: ...fied below The customer or the user of the Compressor Nebuliser should assure that it is used in such an environment Guidance and manufacture s declaration Guidance and manufacture s declaration elect...

Страница 28: ...1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures...

Страница 29: ...ended below according to the maximum output power of the communications equipment 80 MHz to 800 MHz 0 01 0 1 1 10 100 3 3 2 0 7 1 1 0 8 3 7 0 9 6 3 0 3 3 3 2 7 6 1 1 9 7 3 7 9 8 6 3 3 3 3 3 2 7 6 6 1...

Страница 30: ...28 15 Optional parts and accessories Nebuliser Kit Mouthpiece Air Filters x 5 compressor Air Tube PVC 100cm Instruction Manual 21 2 Adult Mask PVC Option Child Mask PVC...

Страница 31: ...ternational Holding Corp GmbH Europe Address Eiffestrasse 80 20537 Hamburg Germany Distributor 0197 Shenzhen Kingyield Technology Co Ltd Section C1 2 FuHai Industrial Zone Fuhai Road FuYong Town Bao a...