4
AIR/HYDRAULIC BOTTLE JACK
50
FAN
Personal Safety
1.
Stay alert.
Watch what you are doing and use common sense when operating the tool. Do not use the tool while tired or
under the influence of drugs, alcohol, or medication. A moment of inattention while operating the tool increases the risk
of injury to persons.
2.
Dress properly. Do not wear loose clothing or jewellery. Contain long hair. Keep hair, clothing, and gloves away from
moving parts.
Loose clothes, jewellery, or long hair increases the risk of injury to persons as a result of being caught
in moving parts.
3.
Avoid unintentional starting.
Be sure the switch is off before connecting to the air supply. Do not carry the tool while
touching the switch or connect the tool to the air supply with the switch on.
4.
Do not overreach. Keep proper footing and balance at all times.
Proper footing and balance enables better control of the
tool in unexpected situations.
5.
Use safety equipment.
A dust mask, non-skid safety shoes and a hard hat must be used for the applicable conditions.
6.
Always wear eye protection.
Wear ANSI-approved safety goggles.
7.
Always wear hearing protection when using the tool.
Prolonged exposure to high intensity noise is able to
cause hearing loss.
Unpacking
Unpack all the components from the box.
When unpacking the Air/Hydraulic bottle jack carefully inspect for any damage that may have occurred during transit.
Check for loose parts, missing parts or damaged parts.
1. Ensure all packaging materials are disposed of as per your local council guide lines.
Bleeding / Venting Trapped Air
Note:
Before first use, the hydraulic ram may need to be purged. Some air may intrude in the hydraulic system due to movement
during shipping. Air bubbles can become trapped inside the hydraulic system, thereby reducing the efficiency of the Jack.
Purge air from the system if efficiency drops.
1.
Assemble the two handles (8) together, ensure that pins align with slots.
2.
Place the slotted end of the handles (8) over the release valve (4) and turn 1-1/2 turns counter-clockwise.
Remove the oil filler plug (9) on the side of the jack reservoir.
3.
Put the Handles (8) into the Manual Pump Lever (11) and rapidly pump the Handle (8) ten times to purge air from the hydrau-
lic system.
4.
Use the Handle (8) to turn the Release Valve (4) clockwise until tight.
5.
Top off Jack Reservoir with a high quality hydraulic jack oil and re-install the oil filler plug (9)
OPERATION
Before first using jack carry out the following preparation:
1.
Check oil level -
Open release valve (4) with handle (8) not more than two turns and press down on saddle (1) to ensure piston
is fully down, then remove oil filler plug (9). Oil should be level with bottom of filler hole. Adjust level as necessary and
replace oil filler plug (9)
2.
Bleed system
- refer to the above “Bleeding/Venting Trapped Air”.
3.
Lubricate -
Oil the pivots of the manual pump mechanism and the screw thread of the saddle (1) post. Put two or three drops
of air tool oil into the inlet of the air inlet (7). Connect to air supply and operate for three seconds to distribute lubricant.
4.
Air supply -
An in-line filter is recommended.
Содержание K12130