6
AIR/HYDRAULIC BOTTLE JACK
50
FAN
4.
OIL REPLACEMENT:
a) Place Jack in an upright position.
b) Completely lower the Ram.
c) Remove the Oil Filler Plug (9) and keep it clean.
d) Fill Reservoir with high-quality hydraulic jack oil to the lower rim of the oiul fill hole.
e) Purge air from the hydraulic system as previously described on Bleeding / Venting Trapped Air on page 4.
f) Top off with more hydraulic oil.
g) Replace Oil Filler Plug (9).
Repairing Jack/Spare Parts
There are no user serviceable parts except as outlined above. Only trained, licensed and certified repair personnel should attempt
any repairs or replacing of parts. Any modifications to this jack, except those performed by the manufacturer, or their designee, will
void all warranties both written and implied.
Caring for the environment
When a tool is no longer usable it should not be disposed of with household waste, but in an environmentally friendly way.
Please recycle where facilities exist. Check with your local council authority for recycling advice.
Recycling packaging reduces the need for landfill and raw materials. Reuse of recycled material decreases pollution
in the environment. Please recycle packaging where facilities exist. Check with your local council authority for recycling advice.
DESCRIPTION OF SYMBOLS
SYMBOL
PROPERTY OR STATEMENT
SYMBOL
PROPERTY OR STATEMENT
n
o
No-load speed
WARNING: marking concerning
Risk of Eye Injury.
Wear ANSI-approved eye pro-
tection.
.../min
Revolutions or reciprocation per minute
WARNING marking concerning
Risk of Hearing Loss. Wear
hearing protection.
psi
Pounds per square inch of pressure
WARNING marking concerning
Risk of Respiratory Injury. Wear
NIOSH-approved dust mask/
respirator.
ft-lb
Foot-pounds of torque
Symbol
property or statement
cFM
Cubic Feet per Minute flow
NpS
National pipe thread, straight
ScFM
Cubic Feet per Minute flow at standard
conditions
NpT
National pipe thread, tapered
Содержание K12130
Страница 8: ...www kincrome com au...