www.kimray.com
HIGH PRESSURE CONTROL VALVE
Installation, Operation & Maintenance Guide
14
Model: PO, PC
DISASSEMBLY
Item
Part No. / Description
Qty
1
Snap Ring
1
2
Retainer
1
3
Wiper
1
4
Packing Box
1
5
O-Ring
1
6
Packing Rings and Sleeve
1
10 Packing Box Assembly
Remove Snap Ring (Item 1).
Remove Retainer (Item 2).
Remove Wiper (Item 3).
Remove O-Ring.
Remove Packing Box and
Packing Ring (Item 6).
Remove Packing Follower (Item 7).
Remove Spring (Item 8).
Remove Cage (item 9).
NOTE:
Using a punch, tap the Packing Rings
and Sleeve through the bottom of the
Packing Box.
Check all parts for damages.
NOTE:
Apply all purpose grease the inside of the
Packing Box before inserting parts.
Insert new Felt Wiper (Item 3).
Insert new Felt Retainer (Item 2).
Insert new Snap Ring (Item 1).
Use all purpose grease on the outside of the
Packing Rings before inserting into the Packing
Box (Item 6).
Use a socket to push the Packing down.
Insert Packing Follower (Item 7).
Re-use Spring (Item 8).
Use a brush or a grease gun to fill the Packing
Box with all purpose grease.
Disassembly
Assembly
Item
Part No. / Description
Qty
7
Follower
1
8
Spring
1
9
Cage
1
✴
Recommended spare parts and stocked as repair kits
9
7
8
6
5
4
3
2
1
✴
✴
✴
✴
Tip:
Use Kimray replacement parts only.
Fig. 10-1
✴
✴
✴
✴