Probe menu
Wire probes and modules with Smart-plus system are automatically recognized from first connection.
The ''
Probe
''
menu only appears when probes or module are connected. This menu allows to view probe
information plugged to
C2, Module, C1
or
wireless connections
.
(See « Connections » p 6 for more information about connections).
Available information are :
•
Sensor type, Serial number, Date of last calibration or adjustement, Probes Status (enabled ou disabled).
On enabled mode, the probe is connected, the measurement is carried out and the value is displayed.
On disabled mode, the probe is connected, the measurement is not carried out and the value is not
displayed.
Pressure
Access
Pressure
function by means of key. With
Pressure
function, you can
access to following sub-functions
-
Hold
- see Air velocity
-
Config.
(Configuration) - see Air velocity
-
Params
(Parameters) - see Air velocity
-
Avg.
(Average) - see Air velocity
-
Rec
(Recording) - see Air velocity
8
IV – Menus
Infos
Measure
Probe display
Params
Pressure
AIRFLOW
Access
Airflow
function by means of key. With
Airflow
function, you can access to following sub-functions
-
Hold –
see Air velocity
-
Area
-
Config.
(Configuration) - see Air velocity
-
Params
(Parameters) - see Air velocity
-
Avg.
(Average) - see Air velocity
-
Rec
(Recording) - see Air velocity
To select vent
Type
press
OK
or
.
Select
Lx W
or
Diam
or
K factor
with arrow buttons
and
. Confirm with
OK
. If K factor is
selected, you must enter value. You can choose a K factor already registered by selecting with
and
. Confirm with
OK
. This factor can be modified by selecting with
and
, then confirm
with
OK
or
. Select
Modify
with
OK
or
. Enter factor by means of arrow keys
and
.
Confirm with
OK
or
.
•
Duct type
Area
Airflow
Functions
Rec.
Config
Params
Veloci.
AutoZ
Airflow
Hold
Probe
Avg.
Alarms
PRESSURE display
AIRFLOW display
Rec.
Config
Params
Area
AutoZ
Press
Hold
Probe
Alarms
Veloci.
Avg.
•
Sizes
Press
or
OK
to enter into
sizes
sub function. You can choose an air vent already registered by selecting it with arrow keys
and
.
Confirm with
OK
or
. This air vent can be modified by selecting it with arrows keys
and
, then Confirm with
OK
or
. Select
Modify
with
OK
or
. Enter sizes by means of arrow keys
and
. Confirm with
OK
or
.
This sub-function allows to compensate for any long-term drifts of the sensing element by a manual adjustment of the zero.
For the ±500 Pa measurement module, self-calibration is performed by the solenoid valve. Once pressing
Autoz
key, the zero is readjusted.
This function can also be automatically performed by using the solenoid valve function.
For others measurement modules, self-calibration is performed by disconnecting the two pressure inlets of the sensor, then by pressing
Autoz
key.
AutoZ
actoolsupply.com
actoolsupply.com