background image

Page 7 of 9 

Killion Industries, Inc. • 1380 Poinsettia Ave., Vista, CA  92081 

Phone (760) 727-5102 • Toll Free (800) 421-5352 • Fax (760) 727-1622 

www.killionindustries.com • [email protected] • [email protected] 

 

 

 

 

If you feel that your refrigerated merchandiser is not operating properly, please review the following list before 
placing a service call: 

 

Troubleshooting Check List 

 

1.

 

Is the refrigerator in a defrost cycle?  Refrigerators periodically go into defrost cycles.  During a defrost 

cycle, the refrigerator thermometer may read above 45

 F.  The thermometer provided with the 

refrigerator measures the air temperature in the back of the case.  This is only the air temperature; the 
product temperature will remain below 45

 F when the case is operating properly.  Wait an hour and 

return to the merchandiser to recheck the temperature. 

2.

 

Do the store conditions exceed 75° F / 55% relative humidity?  Killion Type 1 Refrigerated Display Cases 
are not designed to operate in conditions exceeding 75° F / 55% relative humidity. 

3.

 

Has the compressor stopped running for an extended period of time?  The most common cause is high 

pressure triggering the high pressure safety switch.  This can happen when the condensing coil, or the 
intake filters to the condensing coil, are dirty.  Clean the condensing coil or replace any dirty intake 

filters.  Have a qualified technician locate and reset the high pressure safety switch and restart the case. 

4.

 

Is there at least four feet (48”) between the top of the merchandiser and the store’s ceiling?  Top-
mounted condensing units need this space to properly vent the heat they create.  Nothing can be 

stacked on top of the case, as this also will interfere with proper ventilation. 

5.

 

Are external sources such as heaters, sunrays, drafts, hot tables, etc. introducing heat into the case?  
Move these external sources away from the refrigerated merchandiser or move the merchandiser away 

from these sources. 

6.

 

Is the return air grill on the front of the bottom deck blocked with dust or product?  Remove all product 
and dust from the return air grill to ensure proper airflow. 

7.

 

Is there too much product loaded into the case that it is blocking the air flow from the back of the unit?  

The load limits outlined in the Product Stocking / Load Limits section of this manual must be followed. 

8.

 

Is the case leaking water?  Make sure the condensate pumps are operating properly.  Verify that all the 

drain lines are clear to freely transfer water. 

9.

 

Is the case too warm?  Change the setting switch in the top front of the case (in the compressor area) 
to the “Summer” setting for a cooler temperature. 

10.

 

Is the case too cold?  Change the setting switch in the top front of the case (in the compressor area) to 
the “Winter” setting for a warmer temperature. 

 

If you need further assistance, please call Killion’s customer service 

department at 1-800-421-5352.

 

 

Troubleshooting 

Содержание CFFM-93-57-99

Страница 1: ...Cases are shipped with generic settings Therefore a Qualified Refrigeration Service Technician should properly adjust case settings for each store s unique ambient conditions if necessary 5 Disconnect...

Страница 2: ...TENTS Shipping Examination 1 Location 1 Plumbing Requirements 2 Electrical Supply 2 Refrigerated Display w High Volume Condensate Pump 3 Routine Maintenance 4 Lighting 5 Refrigeration 5 Temperature Co...

Страница 3: ...sources can affect the refrigerator s efficiency Do not enclose refrigerated display case with walls There should be ample space on each side of the condensing unit to facilitate free airflow Closing...

Страница 4: ...ing back into the pump reservoir Make sure that there are no sags in the length where condensate can pool and any bends in the run should be kept to a minimum Electrical Supply A licensed electrician...

Страница 5: ...the drain line coming down from the ceiling 3 Locate the flex tube from the high volume condensate pump with the disconnect fitting attached Screw this into the fitting attached to the store drain lin...

Страница 6: ...Vacuum interior bottom and wipe clean of sediment or deposits in coil drain pan and around condensate pump Wipe evaporator fan blades clean to remove any dirt or film that may be deposited on them Us...

Страница 7: ...necessary these settings can be adjusted by a qualified Refrigeration Service Technician to accommodate a store s unique ambient conditions and for the product being displayed To reset the controller...

Страница 8: ...els with slots intended for air intake or discharge DO NOT dump excess product water into the case This will cause strain on the condensate removal systems that can cause the case or condensate system...

Страница 9: ...Have a qualified technician locate and reset the high pressure safety switch and restart the case 4 Is there at least four feet 48 between the top of the merchandiser and the store s ceiling Top mount...

Страница 10: ...including any warranty of merchantability or fitness for a particular purpose TRANSPORTATION COSTS KILLION will pay the cost of freight for any and all parts under warranty KILLION will not accept ret...

Страница 11: ...n your specific case It is typically located near the compressor 2 Hold down both the i and the x buttons for 5 seconds The parameter SPL will show on the screen 3 Tap the button The screen will show...

Отзывы: