Item Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES

4 Ft, 8 Ft & 12 Ft

A.

7W Standard

Fan Assembly 

(1)

0058698

Fan Motor, Evaporator 
(MO.4410102)

0142780

Fan Blade (FB.0142780)

7W Energy Efficient

Fan Assembly 

(1)

0477654

Fan Motor, Evaporator
(MO.4410545)

0142780

Fan Blade (FB.0142780)

6 Ft Only 

A.

4W Standard 

Fan Assembly  

(1)

0392457

Fan Motor, Evaporator
(MO.4410101)

0382383

Fan Blade (FB.4780617)

4W Energy Efficient

Fan Assembly 

(1)

0477653

Fan Motor, Evaporator
(MO.4410544)

0382383

Fan Blade (FB.4780617)

Item Part #

Description

Wiring Item #

T

HERMOSTATS

B. Optional Adjustable Refrigeration Thermostat (2)

H

EATERS

C.

Canopy Anti-Sweat Heater

(3)

0488621

4 ft (HE.4850616)

0488622

6 ft (HE.4850617)

0488623

8 ft (HE.4850618)

0488624

12 ft (HE.4850619)

L

AMPS

. B

ALLASTS

, LED F

IXTURES AND

P

OWER

S

UPPLY

D. Ballast, Electronic

(4)

0480130

2 lamps (BA.4481676)

0480131

3 lamps (BA.4481654)

0480132

4 lamps (BA.4481677)

E.

Fluorescent Lamp

(5)

Replace with like fixtures

F. 0501213

Power Supply (EP.4481861)

(6)

G.

LED Fixture

(7)

Replace with like fixtures

©2008 HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM

Note:  Revision G adds optional LED lighting (

Pages 1, 3, 4, 8

); adds capacity and weight (

Page 5

).

Содержание impact Excel C2X-LEP

Страница 1: ...7 Fan Motor Evaporator MO 4410101 0382383 Fan Blade FB 4780617 4W Energy Efficient Fan Assembly 1 0477653 Fan Motor Evaporator MO 4410544 0382383 Fan Blade FB 4780617 Item Part Description Wiring Item THERMOSTATS B Optional Adjustable Refrigeration Thermostat 2 HEATERS C Canopy Anti Sweat Heater 3 0488621 4 ft HE 4850616 0488622 6 ft HE 4850617 0488623 8 ft HE 4850618 0488624 12 ft HE 4850619 LAMP...

Страница 2: ...NA 29 1 2 750 41 1 2 1054 29 1 2 749 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 Electrical Service Electrical Field Wiring connection point B RH End of case to center of stub up area 36 1 4 921 60 1 4 1530 84 1 4 2140 108 1 4 2750 132 3 8 3363 Back of case to center of s...

Страница 3: ...tures Add 20 Btu hr ft per shelf row for fluorescent lamps DEFROST DATA C2X LEP Frequency hr 12 Defrost Water lb ft day 6 15 based on case configuration and product loading OFFTIME C2X LEP Time minutes 30 ELECTRIC OR GAS Not Recommended CONVENTIONAL CONTROLS Low Pressure Backup Control C2X LEP Dairy Deli Produce CI CO 19 9 F Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pres...

Страница 4: ...60Hz Energy Efficient 0 39 0 44 0 58 0 77 0 77 230V 60Hz Energy Efficient 0 30 0 32 0 40 0 50 0 50 Maximum Over Current Protection 120V 20 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 15 Canopy Anti sweat Heaters 120V 50 60Hz Standard 0 10 0 15 0 20 0 30 0 30 12 18 24 36 36 Standard Lighting T 8 Fluorescent 1 Row Canopy 0 26 0 51 0 51 0 77 0 77 30 59 59 85 85 Optional Lighting T 8 ...

Страница 5: ...t3 ft 0 29 m3 m ARI Total Display Area 3 Sq Ft Ft 3 11 ft2 ft 0 95 m2 m Shelf Area 4 Sq Ft Ft 5 04 ft2 ft 1 54 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refrigerated Volume less shelving and other unusable space Refrigerated Volume Unit of Length ft3 ft m3 m 3 Computed using ARI 1200 standard methodology Total Display Area ft2 m2 Unit ...

Страница 6: ...or 5 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy 3 Row Canopy 5 4 5 5 Connector W B BL BL R BL R R R Optional Lighting 1 Row Rail B 4 ft 6 ft or 8 ft 10 ft or 12 ft 4 ft 6 ft or 8 ft 10 ft or 12 ft R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND CASE GROUND WARN...

Страница 7: ...ARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Two Rows of Shelves 4 ft case Connector 5 4 5 B W Connector 6 ft or 8 ft case 10 ft or 12 ft case R R W BL BL R B BL BL R 5 4 5 B W R R W BL BL R B BL BL R 5 4 5 B W R R W BL BL R B BL BL R Canopy Anti Sweat Heater...

Страница 8: ...BL 7 7 R BL R BL R BL 7 7 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and LED Light Circuits for Two Rows of Shelves R R B Optional Shelf Lighting LED Fixtur...

Страница 9: ...lves The depth of the shelf used in the top eight 8 shelf hole locations is critical to case performance If a shelf is placed in one of the top eight 8 locations it must comply with the angle depth requirements listed below Maximum Shelf Shelf Angle Depth 0 º 12 in 15 º 14 in or less 30 º 18 in or less 45 º 18 in or less NOTE Shelves placed in the lower positions may be up to 18 in deep when posit...

Страница 10: ...ballast for the canopy and shelf lamps is located behind the canopy on the left hand end when facing case of the merchandiser To access the ballast 1 Remove screws at bottom edge of canopy and rear of light channel 2 Lower light channel which will pivot on hinge 3 Service or replace ballasts as required 4 Reassemble items as they were originally installed NOTE Rail lamp ballast is located in the e...

Отзывы: