19
FINDING
OFF
:
NG will display when no load rotation
GATE MODE
OFF/ONCE/TWICE/
ONCE+CON/TWICE
+CON
ONCE: workpiece in position at once
TWICE: workpiece in position at two times
ONCE+CON: workpiece at position at once plus CONFIRM for
confirmation
TWICE+CON: workpiece at position at two times plus
CONFIRM for confirmation
OFF
TORQUE UNIT kgf.cm/N.m/
lbf.in/kgf.m
Set up torque display unit.
kgf.cm
OPERATION
MODE
STD/ADV
Connection mode.
STD: Standalone mode.
ADV: KL-AMS network system (WIFI/Ethernet) connection
mode.
STD
TORQUE
ALIGNMENT
ON/OFF
Calibration torque switch on/off
Press E/C key to start selection, use Up and Down key to change
to ON, and then press E/C key to confirm.
OFF
SEQUENCE
SET
OFF/MULTI/SINGLE OFF: Disable
MULTI : A Job cycle
SINGLE : Sequence cycle
OFF
POO- POO-… *8 P01-99
Sequence order
0
AUTO
LEARNING
ON/OFF
Automatic learning.
Turn on auto-learning function; wait for the auto-learning to
complete (need to perform brake function), monitor will then
display the screw driving time, torque value, number of screw
turns, and such data will be saved. Above data cannot be 0 in
order to save the parameters after the auto-learning.
OFF
BCODE
LEARNING
ON/OFF
First Code
G1-G5
:
Set Barcode group
Second Code
P1-P99
:
Set PROGRAM Group
CL
:
Clear
DA
:
Disable Screwdriver Functions
EA
:
Disable Relieve
AS
:
Release Screwdriver lock status by OKALL
NS
:
Release Screwdriver lock status by NG
G1-P1
The maximum
length of Barcode
data is 16
characters
Name
Set Up Time and
Value
Function Interpretation
Factory Setting
Value
[4] PASSWORD
A0000
Set up password lock.
A0000
CONTROL VER. V2.XXX
Mainboard version.
V2.XXX
SCREWDRIVER
VER.
V2.XX
Screwdriver version.
V2.XX
Action Limitation
RR/RS
RT
PT
LL
AUTO FORWARD (RR/RS)
V
X
X
X
AUTO REV. TIME (RT)
X
V
X
X
AUTO STOP TIME (PT)
X
X
V
X
RECONFIRM TIME (LL)
X
X
X
V
Remarks: V - setting available, X - OFF