Device Operation Mode

0~3

String

1 Byte

128

Mode:
 0 : ADV (Connection mode),
 1 : STD (Standalone  Mode),
 2 : ALI (Alignment mode) ,
 3 : SET(Setting mode)

17

Tool Stop Status

0~9,A~

J

String

1 Byte

130

Tool Stop Status (0: None , 1:NS, 2:AS, 3:E3, 4:E4, 5:E5, 7:E7, 8:E8, 9:BS, A:EPC,
B:ESC, C:ES, D:Er, E:C1, F:C2, G:C4, H:C5 I:ESD J:EA)
EA has an abnormal communication in CTDS 1.7X version.
The appearance of EA in MCTDS5 means bad RS485 communication.
C3 appears for AS so it will send 2.
BS only appear on the MCTDS5.

18 Torque Filter

0~250,255

String

3 Byte

132-134

Torque filter 

(0:

No filter

,1-2

5

0 : F

ilter count,255:Unlimited Filter 

)

CTDS 2.124 and MCTDS5 2.005 version  add infinite filtering and modify  20
times to 250 times

19

Pre-filtering torque

000

0.00

00

~

0

550.00

00

String

9 Byte

136-144

Pre-filtering torque
This field is only available for CTDS 2.124 and MCTDS5 2.006.

20 Current value

00000-65535

String

5 Byte

146-150

Current value
This field is only available for CTDS 2.124 and MCTDS5 2.006.

21

Year

000

1~9999

String

4 Byte

152-155

Year

22

Month

0

1~

12

String

2 Byte

157-158

Month

23

Date

0

1~

31

String

2 Byte

160-161

Date

24

Hour

00~23

String

2 Byte

163-164

Hour(24 hours)

25

Minute

0

0~

59

String

2 Byte

166-167

Minute

26

Second

0

0~

59

String

2 Byte

169-170

Second

27

Check Sum

0000-9999

String

4 Byte

172-175

28

Key Code

0000-9999}

String

5 Byte

177-181

Key Code+Tail

29

ASCII code LF

30

ASCII code CR

{DATA0, ..... }Total:181 Byte,28 Field

Remark

4. {CMD0} Data format/example

Field

Parameter

Value

Data Type

String Length

Position

Description

1

CMD

{CMD0

String

5 Byte

1-5

Command code

2

Device Name

0

~1

String

1 Byte

7

Device Name(0: AMS, 1: DAS)

3 unused

0

String

1 Byte

9

unused

4 unused

0

String

1 Byte

11

unused

5 unused

0

String

1 Byte

13

unused

6 unused

0

String

1 Byte

15

unused

7 unused

0

String

1 Byte

17

unused

8

Year

0001

~9999

String

4 Byte

19-22

Year

9

Month

0

1~

12

String

2 Byte

24-25

Month

10

Date

0

1~

31

String

2 Byte

27-28

Date

11

Hour

00~23

String

2 Byte

30-31

Hour(24 hours)

12

Minute

0

0~

59

String

2 Byte

33-34

Minute

13

Second

0

0~

59

String

2 Byte

36-37

Second

14

Check Sum

0000-9999

String

4 Byte

39-42

15

Key Code

0000-9999}

String

5 Byte

44-48

Key Code+Tail

16

ASCII code LF

17

ASCII code CR

Remark

Communication interface  :

Connection RS232 :

PORT1

    Connection method:KL-MCTDS5

PORT2

Remark

{CMD0, ..... }Total: 48Byte,15 Filed

 RS-232C 9 Pin Female (DCE)  to PC or PLC (DTE)

Item 1 to 28 are separated by  ","  (ASCII 0x2c)

※When the trip information (DATA0) is continuously transmitted, it can be judged by the field six。

{CMD0,0,0,0,0,0,0,2018,09,03,18,45,19,2112,7550}

1.Item 1 to 15 are separated by  ","  (ASCII 0x2c)
2.Reply to CMD0 when the time is inconsistent or repeat {DATA0}

1.Barcode scanner

Connection method:KL-CTDS

    Connection method:KL-MCTDS5

2.WIFI module

  Connection method:KL-CTDS

                             

Содержание KL - CTDS

Страница 1: ...BNK Torque Display User Manual Model KL CTDS Ver 2 00 KILEWS INDUSTRIAL CO LTD http www kilews com tw Y2F167 2 018 20200323 V2127...

Страница 2: ...driver action time 999 9 display number of turns Q Display torque value S Display status OK NGT NGQ NGC OKALL Up Key Setting mode Up key switch function Down Key Setting mode Down key switch function...

Страница 3: ...l torque SKP BE32HL BN Anti interference cable Connect Barcode Scanner Connect DAS BNK series power torque SKP 40B HL 800 SKP 40B HL BNK800 series BN Anti interference cable Connect Barcode Scanner Co...

Страница 4: ...nd the red LED is lit up The torque range value is 0 550KGF L 0 0 H 550 00 Name Set Up Time and Value Function Interpretation Factory Setting Value THREAD LIMIT 0 0 999 9 Turns Number of screw turns L...

Страница 5: ...sequential number 1 GEAR RATIO 1 99 Set up the gear ratio and set up such value according to each electric screwdriver model 14 SCREWDRIVER ID Tool product serial number Tool product serial number Be...

Страница 6: ...ING ON OFF Automatic learning Turn on auto learning function wait for the auto learning to complete need to perform brake function monitor will then display the screw driving time torque value number...

Страница 7: ...iver then starts the activation of Reverse rotation 2 External switch on CN1 is in close circuit with GND CLOSE during the reverse rotation signal CN3 GND Open OPEN the screwdriver then starts the act...

Страница 8: ...During open circuit CN7 CN8 are disconnected CN 8 COM GND This pin refers to the OK signal connection negative end CN 9 NG NOK When there is an error operation CN9 and 10 are conducted During close c...

Страница 9: ...ic screwdriver motor is abnormal the action of the electric screwdriver is stopped and the LED displays this symbol representing that the screwdriver is currently under motor startup abnormality prote...

Страница 10: ...ns 9 1 Hardware description Connect Bar code Reader to port 1 on CTDS through RS232 9 2 Barcode Reader Set function options Serial interface Record Suffix CR Baud Rate 9600 BPS Data Frame Data Bits 8...

Страница 11: ...piece comes in for fastening purpose you need to scan the workpiece or pre prepared barcode before the tool can be used and switch to the correct group 9 3 2 Barcode Reader can be used for cancels the...

Страница 12: ...nd accessories KILEWS would not responsible for if it used with a non KILEWS screwdriver or spare parts for repair purpose caused malfunction or poor quality resulting in failure of all guarantees 3 K...

Страница 13: ...ten shut off or the switching power and the KL CTDS and electric screwdriver is required return for repair service 5 Do not disassemble the screwdriver of the electric screwdriver to try to fix it 6 W...

Страница 14: ...use column 6 no of total tightening on controller to increase by 1 External device needs to reply CMD0 if not CMD0 will keep on sending DATA0 only update date time and column 6 no of total tightening...

Страница 15: ...yclic communication Controller write to external device REQ0 send sec CMD0 send sec Controller respond time Barcode input to controller REQ1 Controller feedback time CMD0 Data write in to controller D...

Страница 16: ...nd 00 59 String 2 Byte 55 56 Second 9 Check Sum 0000 9999 String 4 Byte 58 61 10 Key Code 0000 9999 String 5 Byte 63 67 Key Code Tail 11 ASCII code LF 12 ASCII code CR REQ1 Total 67Byte 10 Field Remar...

Страница 17: ...2 175 28 Key Code 0000 9999 String 5 Byte 177 181 Key Code Tail 29 ASCII code LF 30 ASCII code CR DATA0 Total 181 Byte 28 Field Remark 4 CMD0 Data format example Field Parameter Value Data Type String...

Страница 18: ...NO THIRD ANGLE PROJECTION ITEM NO DES BY CHKD BY APPD BY TITLE CUSTOMER DWG NAME DWG NO MATERIAL DATE DATE DATE UNIT SHRINK SCALE SHT NO OF SHTS 10 3 4 6 7 8 9 11 12 13 14 15 16 17 18 19 20 20 21 22 2...

Страница 19: ...5mm M3 5mm 6 10 E31726 1 20Pin Plug 20P 1 11 C50217 2 Terminal Cover 1 12 CH30222 1 Srew M3 0 5P 5L I M3 0 5P 5L I 2 13 EG31538 3 PCB IO IO 1 14 CH20505 6 Srew M3 5mm M3 5mm 3 15 CH30222 1 Srew M3 0 5...

Отзывы: