PART NO. Z1-005-550, IA004953

Jan. 2017

400W Type

  

800W Type 

 

1600W Type

PWR400L PWR800L PWR1600L

PWR400M PWR800M PWR1600M

PWR400H PWR800H PWR1600H

Setup Guide

Regulated DC Power Supply PWR Series

Thank you for purchasing the PWR regulated DC power supply se-
ries.
The PWR Series are constant voltage/current automatic crossover 
power supplies that are capable of delivering voltages and currents 
in a wide operating range within the rated output power.

Features

•  Power-factor improvement circuit

The power-factor improvement circuit reduces the effects of har-
monic currents on the power line.

•  High efficiency

The high power conversion efficiency reduces the cost of power 
and the cost of heat radiation design during system configura-
tion.

•  Communication functions

Equipped with a digital remote control function through TP-BUS 
(Twist Pair-BUS) communication (The total length of TP-BUS is 
200 m). By combining with Kikusui’s PIA4800 Series Power Sup-
ply Controller, systemization for applications such as an auto-
matic tester is possible.

•  Master-slave operation

Output voltage or output current can be expanded by connect-
ing multiple power supplies of the same model in series (only 
on the L type) or in parallel. This feature allows slave units to be 
controlled from a single master unit.

KIKUSUI ELECTRONICS CORP.

1-1-3, Higashiyamata, Tsuzuki-ku, Yokohama, 224-0023, Japan
TEL: +81-45-593-0200 Fax: +81-45-593-7571

The contents of this manual may not be reproduced, in whole or in part, without the 
prior consent of the copyright holder.
The specifications of this product and the contents of this manual are subject to 
change without prior notice.

WEBSITE

http://www.kikusui.co.jp/en

The newest version of the PWR manual can be downloaded 
from Download service of Kikusui website.

© 2012

Содержание PWR1600H

Страница 1: ...al remote control function through TP BUS Twist Pair BUS communication The total length of TP BUS is 200 m By combining with Kikusui s PIA4800 Series Power Sup ply Controller systemization for applica...

Страница 2: ...GB1002 Rating 250Vac 10A 85 10 0790 or or 1 pc M3 112 012 1 pc M3 112 015 CD ROM 1 pc Setup Guide This guide 1 pc Quick Reference English 1 pc Japanese 1 pc Safety information 1 pc Power cord for the...

Страница 3: ...lost or soiled a new copy can be provided for a fee To replace or purchase a manual please contact your Kikusui agent or distributor At that time inform your agent or distributor of the Part No writt...

Страница 4: ...igured in a way that satisfies the equation output voltage x output current rated output voltage the actual output is limited by the power limit approx 105 of the rated output power and the output vol...

Страница 5: ...Rated output current Extended operating area Intermittent extended operating area Maximum output current Continuous extended operating area Extended operating area Continuous output is possible At amb...

Страница 6: ...d the product to prevent electric shock Connect the ground terminal to earth ground Connecting the Power Cord Precautions Concerning Installation This product cannot be used while it is on its side Th...

Страница 7: ...difficult consult your Kikusui agent or distributor The power cord with a three prong plug is used to disconnect the PWR from the AC line in an emergency Connect the power plug to an easily accessibl...

Страница 8: ...e corre sponding input terminals L N and GND are correct Note Turn off the circuit breaker of switchboard to disconnect the PWR from the AC line in an emergency Circuit breaker of switchboard requirem...

Страница 9: ...es with the input rating of the PWR The voltage that can be applied is any of the nominal power supply voltages in the range of 100 VAC to 240 VAC The frequency is 50 Hz or 60 Hz 2 Check that the POWE...

Страница 10: ...switch is turned off 2 Check that the power cord is correctly connected 3 Turn the POWER switch on Push the side of the POWER switch to turn the PWR on If an odd sound odd odor fire or smoke occurs a...

Страница 11: ...ff The PWR stores the panel settings excluding output on off condi tion immediately before the POWER switch is turned off For these items the PWR starts up using the settings that existed when the POW...

Страница 12: ...e Ammeter reading average value Preset constant current value Ammeter reading average value Load that generates reverse current to the power supply The PWR cannot absorb reverse current from the load...

Страница 13: ...PWR and the load in series CAUTION To protect the load and the PWR select a DRP that com plies with the following conditions Reverse voltage withstand capacity of at least twice the rated output volta...

Страница 14: ...mbient temperature and thermal resistance to the outside Table shows the allowable capacity of current that can flow through a heat resistant PVC wire single wire having a maximum allowable temperatur...

Страница 15: ...voltage drop exceeds this level wires having a greater sectional area should be used Nominal cross sectional area of wires and allowable currents Nominal Cross Sectional Area mm2 AWG Reference Cross S...

Страница 16: ...of AWG18 or higher to make the connection This M3 screw is fastened to the pos terminal before factory shipment If you want to connect the chassis connection wire to the neg output terminal as shown...

Страница 17: ...out screws 2 Align the hook of the bottom cover to the groove lo cated to the side of the output terminal 3 Align the bottom cover with the top cover and fix them in place using the screws attached to...

Страница 18: ...utput terminal on the front panel Do not use the terminal with the front output terminal cover removed In addition be sure to attach the OUT PUT terminal cover on the rear panel Possible overheating o...

Страница 19: ...indows and Visual Basic are registered trademarks of Microsoft Corporation in the United States and or other countries All company names and product names used in the PWR manual are trademarks or regi...

Страница 20: ...i Name of hazardous materials and symbol of element in the equipment and quantity Name of part Hazardous material and symbol of element Pb Hg Cd Cr VI PBB PBDE Printed circuit board assemblies Interna...

Отзывы: