PCR-LE2 series
5
Handling the Terminal Block Tray (PCR6000LE2/ PCR9000LE2)
The PCR-LE2 Series AC INPUT, OUTPUT terminal block, SENSING
terminal block, and J1 to J4 connectors are designed so that they
can only be wired after you first pull out the terminal block tray.
The terminal box covers ensure that you don’t touch the unwired
terminals. Use a Phillips-head screwdriver to insert and remove the
screws.
1
Check that the POWER switch is turned off.
2
Loosen the six terminal box cover screws, and then
slide the three covers up.
M3 x 6
3
Remove the two terminal block tray screws, and
then pull the tray out.
M4 x 2
4
Pull out the stopper to lock the terminal block tray
in place.
Stopper
5
Connect the wires and cables to the terminal block
and connectors as necessary.
6
Return the stopper to its previous position.
7
Return the terminal block tray to its previous posi-
tion, and then attach the two screws that you re-
moved in step 3
If you do not insert the terminal block tray all the way into
its storage compartment, an electric current will not flow
through the PCR-LE2 even if the POWER switch is turned
on.
8
Slide the two terminal box covers down until they
are touching the wires, and then use the four
screws to fix the terminal box covers in place. Slide
the terminal box cover all the way down if none of
their terminals have wires connected to them, and
use the two screws to fix the covers in place.
The figure below is an example for when the OUTPUT ter-
minal blocks for single-phase output are in use.