OT01-PCR-LA/2
Specifications 8-3
The above table shows the comprehensive capability achieved when the PCR-LA
AC power supplies are operated in parallel. The remaining speci
fi
cations comply
with those for a PCR-LA AC power supply.
(*1) The value measured at the OUTPUT terminal board of the master unit
(*2) For output voltage of 80 V to 150 V/160 V to 300 V and a load power factor of
1
(*3) For output voltage of 80 V to 150 V/160 V to 300 V and a load power factor of
1. The value speci
fi
ed is the output-voltage variation obtained using 200 Hz as
a reference.
(*4) With respect to changes from an output current of 0 A to the rating and vice
versa when the output voltage range is 100 V/200 V and the load power factor
is 1
(*5) The resolution changes in accordance with the output capacity achieved during
parallel operation. The accuracy is the same as that of the PCR-LA AC power
supply when the zero calibration function is performed.
8.1.3
Single-phase, Three-wire Operation
(*6) Phase difference between output voltages (phase voltages) when each phase is
seen from the neutral point in the condition in which the phase difference is not
varied (phase difference between each phase: 120°)
(*7) The following are examples of the results obtained through angular conversion
of the noted expression at speci
fi
c frequencies:
Within 180° ± 0.5° (for 60-Hz output)
Within 180° ± 1.2° (for 400-Hz output)
Output phase voltage’s phase difference
Output voltage phase difference (*6)
Within 180° ± (0.4° + 5
μ
s)
Within 180° ± (0.4° + f
0
x 1.8 x 10
-3
°). “f
0
” stands for the output fre-
quency. (*7)
Power line abnormality simulation
(speci
fi
cations different from those achieved in single-phase parallel operation.)
Item
Setting rangec
Resolutiond
Setting accuracy
T1
x 1deg
0 deg – 360 deg
1 deg
± 1.5 ms
x 1ms
0 ms – 999 ms
1 ms
± 1 ms
T3
x 1
0 ms – 9999 ms
1 ms
± (0.1 %+1 ms)
V(T3)
0 V to rated voltage
(phase voltage setting)
—
Содержание OT01-PCR12000LA/2
Страница 10: ...VIII Contents OT01 PCR LA 2 ...
Страница 16: ...1 6 General OT01 PCR LA 2 ...
Страница 44: ...2 28 Installation and Preparation for Use OT01 PCR LA 2 ...
Страница 56: ...4 8 Part Names and Functions OT01 PCR LA 2 ...
Страница 64: ...5 8 Single phase Parallel Operation OT01 PCR LA 2 ...
Страница 82: ...6 18 Single phase Three wire Operation OT01 PCR LA 2 ...
Страница 94: ...1 2 Index OT01 PCR LA 2 ...
Страница 95: ......
Страница 96: ...OUTPUT EXPANSION KIT OT01 PCR LA 2 OPERATION MANUAL ...