background image

5

2. Carbon Monoxide Alarm: What To Do When the Alarm Sounds

note: 

This is not a carbon monoxide (CO) alarm, but will receive and transmit a CO alarm signal (with voice mes-

sage) from an interconnected CO or combination smoke / CO alarm.

Carbon monoxide (CO) alarm pattern is four quick beeps with voice “Warning! Carbon Monoxide” repeating every 5 

seconds. The red LED blinks in time with alarm pattern.

 WArnIng:  cArbon monoxIde AlArm ActIVAtIon IndIcAteS the preSence of cArbon mon-

oxIde (co) At hIgh concentrAtIonS WhIch cAn KIll yoU.

1)

 Operate the Test/Hush button. 

note:

 Pressing the button on the initiating alarm unit (green LED flashing every sec-

ond) will silence the alarm notification, including all interconnected units. If the unit goes into alarm mode again within 

six minutes, it is sensing high levels of CO which can quickly become a dangerous situation.

2)

 Call your emergency services (Fire Department or 911).  

emergency phone #: _______________________

3)

 Immediately move to fresh air — outdoors or by an open door / window. Do a head count to check that all persons are 

accounted for. Alert small children in the home as well as anyone else that might have difficulty recognizing the impor-

tance of the alarm sounding or that might have difficulty leaving the area without help. Do not reenter the premises nor 

move away from the open door/window until the emergency services responders have arrived, the premises have been 

aired out, and your alarm remains in its normal condition.

4)

 After following steps 1-3, if the alarm reactivates within a 24 hour period, repeat steps 1-3 and call a qualified appli-

ance technician to investigate sources of CO from fuel burning equipment and appliances, and to inspect for proper 

operation of equipment.

If problems are identified during this inspection, have the equipment serviced immediately. Note any combustion equipment 

not inspected by the technician and consult the manufacturer’s instructions, or contact the manufacturer directly for more 

information about CO safety and the equipment. Make sure that motor vehicles are not, or have not been, operating in a garage 

attached or adjacent to the residence. Never restart the source of a CO problem until it has been corrected. Never ignore the 

sound of the alarm!

  

note:  

See Section RECOGNIZING NUISANCE ALARMS, for nuisance alarm situations.

Содержание P4010DCS-W

Страница 1: ...onnect Battery Operated Model P4010DCS W Model P4010LDCS W Safety Light Wire Free Interconnect You do NOT need a home wi fi system to use these units Multiple wireless units create their own independe...

Страница 2: ...never play with the unit Your Kidde Smoke Alarm was designed for use in a residential environment It is not designed for use in a recreational vehicle RV or boat Note Please thoroughly read this user...

Страница 3: ...7 Recommended Locations For Smoke Alarms 10 8 Locations To Avoid 12 9 Activation And Wireless Alarm Network 13 9 1 Setting Up A Wireless Alarm Network 14 9 2 Adding Another Device to an Existing Wire...

Страница 4: ...it If the inside of the door is cool place your shoulder against it open it slightly and be ready to slam it shut if heat and smoke rush in If the escape route requires you to go through smoke stay cl...

Страница 5: ...accounted for Alert small children in the home as well as anyone else that might have difficulty recognizing the impor tance of the alarm sounding or that might have difficulty leaving the area withou...

Страница 6: ...initiating alarm unit Push test button to clear Alarm Memory NOTE stan dard test sequence will follow Push release button again to cancel test Smoke Alarm Hush Mode SMART HUSH CONTROL Red LED blinks e...

Страница 7: ...nd of Unit Life Hush Mode after push release Test Hush button during End of Life Voice Temporarily Silenced End of Unit Life chirps silenced for 24 hrs 7 days after End of Unit Life chirps begin the c...

Страница 8: ...the label prior to installing the unit Product Features and Specifications Temperature Operating Range 40 F 4 4 C to 100 F 37 8 C Humidity Operating range up to 95 RH non condensing Audible Alarm 85 d...

Страница 9: ...n sensing alarms may detect invisible fire particles associated with fast flaming fires sooner than photoelectric alarms Photoelectric sensing alarms may detect visible fire particles associated with...

Страница 10: ...the room Ceiling mounting is preferred in ordinary residential construction ANYWHERE ALONG THIS BOLD SURFACE Locations permitted for smoke alarms and smoke detectors on tray shaped ceilings ANYWHERE A...

Страница 11: ...269 Mobile Home Installation Modern mobile homes have been designed and built to be energy efficient Install smoke alarms as recommended above In older mobile homes that are not well insulated compare...

Страница 12: ...insect infested areas Smoke alarms should not be installed within 3 ft 9m of the door to a bathroom containing a tub or shower forced air supply ducts used for heating or cooling ceiling or whole hou...

Страница 13: ...ttery cannot be turned off and can only be discharged at the end of product life If the alarm is removed from the mounting plate the battery will remain active See Permanently Disable Alarm Discharge...

Страница 14: ...to connect Follow Quick Start instructions NOTE If no further steps are taken within 15 minutes of initial power up a voice prompt No devices found not connected will be heard once and the wireless f...

Страница 15: ...ation for your alarm attach the mounting bracket to the wall or ceiling To ensure aesthetic alignment of the alarm with the hallway or wall the A line on the mounting bracket must be parallel with the...

Страница 16: ...ase button You will hear Searching for other devices Light will pulse green and device will sound a continuous Sonar ping until step E is completed d Relax and wait Wait until the new device has conne...

Страница 17: ...hallway or wall the A line on the mounting bracket must be parallel with the hallway when ceiling mounted or horizontal when wall mounted Install the alarm fully on the mounting bracket by rotating th...

Страница 18: ...s Ready to connect follow quick start instructions Device has been reset See Section 9 1 to begin set up of a new wireless alarm network or Section 9 2 for adding this device to an existing alarm netw...

Страница 19: ...the electronic circuitry horn speaker and battery are working If the alarm or voice does not sound or gives erratic or low volume sound the unit must be replaced See Permanently Disable Alarm Dischar...

Страница 20: ...ou can verify that it is not a life threatening situation you can push the button on the initiating unit green LED flashing every second to silence the alarm for 8 10 minutes If the smoke is not too d...

Страница 21: ...tiating unit If you suspect a nuisance alarm situation you can use this feature to help you locate the initiating alarm unit s in a wireless alarm interconnect system Push the button on any non initia...

Страница 22: ...G NO SERVICEABLE PARTS INCLUDED DO NOT ATTEMPT TO OPEN THE ALARM FOR ANY REASON Do not try to repair the alarm yourself Low Battery This alarm is equipped with a low battery monitor circuit If the bat...

Страница 23: ...ill no longer function Once the alarm battery has been discharged the alarm cannot be mounted onto the mounting plate or reactivated To Permanently Disable Alarm Discharge Battery Rotate the alarm cou...

Страница 24: ...de and the Red LED is blinking a fault code of 10 or 14 flashes after a Test Hush button push the alarm may be in need of cleaning After cleaning press the Test Hush button If the fault does not clear...

Страница 25: ...o test your plan before an emergency You may not be able to reach your children It is important they know what to do Familiarize everyone with the sounds of the smoke alarm and train them to leave you...

Страница 26: ...t can result in improper operation California State Fire Marshal Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household a...

Страница 27: ...io or television reception the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between...

Страница 28: ...acturer be liable for loss of use of this product or for any indirect special incidental or consequential damages or costs or expenses incurred by the consumer or any other user of this product whethe...

Отзывы: