nfpA (national fire protection Association)

Fire Safety in the Home:  

NFPA 72 is intended to 

provide reasonable safety for persons in family 

living units. Reasonable fire safety can be produced 

through the following three-point program: (1) 

Minimizing fire hazards (2) Providing fire-warning 

equipment (3) Having and practicing an escape plan.

Smoke detection – Are more Alarms desirable?

The required number of smoke alarms might not 

provide reliable early warning protection for those 

areas separated by a door from the areas protected 

by the required smoke alarms. For this reason, it is 

recommended that the householder consider the use of additional smoke alarms for those areas for increased protection. 

The additional areas include the basement, bedrooms, dining room, furnace room, utility room, and hallways not protected 

by the required smoke alarms. The installation of smoke alarms in attics (finished or unfinished), garages, or within 6’ of a 

heating or cooking appliance is not normally recommended, as these locations occasionally experience conditions that can 

result in improper operation.

california State fire marshal

Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the 

household as follows: A smoke alarm installed in each separate sleeping area (in the vicinity, but outside the bedrooms), 

heat or smoke detectors in the living rooms, dining rooms, bedrooms, kitchens, hallways, attics, furnace rooms, closets, 

utility and storage rooms, basements and attached garages.

For your information, the National Fire Protection  

Association’s Standard 72 reads:  Where required by other 

governing laws, codes, or standards for a specific type of 

occupancy, approved single and multiple-station smoke 

alarms shall be installed as follows:

1. 

In all sleeping rooms and guest rooms

2. 

Outside of each separate dwelling unit sleeping area, 

within 21 ft (6.4 m) of any door to a sleeping room, 

with the distance measured along a path of travel

3. 

On every level of a dwelling unit, including base-

ments

4. 

On every level of a residential board and care 

occupancy (small facility), including basements and 

excluding crawl spaces and unfinished attics

5. 

In the living area(s) of a guest suite

6. 

In the living area(s) of a residential board and care 

occupancy (small facility)

Содержание P4010DCS-W

Страница 1: ...onnect Battery Operated Model P4010DCS W Model P4010LDCS W Safety Light Wire Free Interconnect You do NOT need a home wi fi system to use these units Multiple wireless units create their own independe...

Страница 2: ...never play with the unit Your Kidde Smoke Alarm was designed for use in a residential environment It is not designed for use in a recreational vehicle RV or boat Note Please thoroughly read this user...

Страница 3: ...7 Recommended Locations For Smoke Alarms 10 8 Locations To Avoid 12 9 Activation And Wireless Alarm Network 13 9 1 Setting Up A Wireless Alarm Network 14 9 2 Adding Another Device to an Existing Wire...

Страница 4: ...it If the inside of the door is cool place your shoulder against it open it slightly and be ready to slam it shut if heat and smoke rush in If the escape route requires you to go through smoke stay cl...

Страница 5: ...accounted for Alert small children in the home as well as anyone else that might have difficulty recognizing the impor tance of the alarm sounding or that might have difficulty leaving the area withou...

Страница 6: ...initiating alarm unit Push test button to clear Alarm Memory NOTE stan dard test sequence will follow Push release button again to cancel test Smoke Alarm Hush Mode SMART HUSH CONTROL Red LED blinks e...

Страница 7: ...nd of Unit Life Hush Mode after push release Test Hush button during End of Life Voice Temporarily Silenced End of Unit Life chirps silenced for 24 hrs 7 days after End of Unit Life chirps begin the c...

Страница 8: ...the label prior to installing the unit Product Features and Specifications Temperature Operating Range 40 F 4 4 C to 100 F 37 8 C Humidity Operating range up to 95 RH non condensing Audible Alarm 85 d...

Страница 9: ...n sensing alarms may detect invisible fire particles associated with fast flaming fires sooner than photoelectric alarms Photoelectric sensing alarms may detect visible fire particles associated with...

Страница 10: ...the room Ceiling mounting is preferred in ordinary residential construction ANYWHERE ALONG THIS BOLD SURFACE Locations permitted for smoke alarms and smoke detectors on tray shaped ceilings ANYWHERE A...

Страница 11: ...269 Mobile Home Installation Modern mobile homes have been designed and built to be energy efficient Install smoke alarms as recommended above In older mobile homes that are not well insulated compare...

Страница 12: ...insect infested areas Smoke alarms should not be installed within 3 ft 9m of the door to a bathroom containing a tub or shower forced air supply ducts used for heating or cooling ceiling or whole hou...

Страница 13: ...ttery cannot be turned off and can only be discharged at the end of product life If the alarm is removed from the mounting plate the battery will remain active See Permanently Disable Alarm Discharge...

Страница 14: ...to connect Follow Quick Start instructions NOTE If no further steps are taken within 15 minutes of initial power up a voice prompt No devices found not connected will be heard once and the wireless f...

Страница 15: ...ation for your alarm attach the mounting bracket to the wall or ceiling To ensure aesthetic alignment of the alarm with the hallway or wall the A line on the mounting bracket must be parallel with the...

Страница 16: ...ase button You will hear Searching for other devices Light will pulse green and device will sound a continuous Sonar ping until step E is completed d Relax and wait Wait until the new device has conne...

Страница 17: ...hallway or wall the A line on the mounting bracket must be parallel with the hallway when ceiling mounted or horizontal when wall mounted Install the alarm fully on the mounting bracket by rotating th...

Страница 18: ...s Ready to connect follow quick start instructions Device has been reset See Section 9 1 to begin set up of a new wireless alarm network or Section 9 2 for adding this device to an existing alarm netw...

Страница 19: ...the electronic circuitry horn speaker and battery are working If the alarm or voice does not sound or gives erratic or low volume sound the unit must be replaced See Permanently Disable Alarm Dischar...

Страница 20: ...ou can verify that it is not a life threatening situation you can push the button on the initiating unit green LED flashing every second to silence the alarm for 8 10 minutes If the smoke is not too d...

Страница 21: ...tiating unit If you suspect a nuisance alarm situation you can use this feature to help you locate the initiating alarm unit s in a wireless alarm interconnect system Push the button on any non initia...

Страница 22: ...G NO SERVICEABLE PARTS INCLUDED DO NOT ATTEMPT TO OPEN THE ALARM FOR ANY REASON Do not try to repair the alarm yourself Low Battery This alarm is equipped with a low battery monitor circuit If the bat...

Страница 23: ...ill no longer function Once the alarm battery has been discharged the alarm cannot be mounted onto the mounting plate or reactivated To Permanently Disable Alarm Discharge Battery Rotate the alarm cou...

Страница 24: ...de and the Red LED is blinking a fault code of 10 or 14 flashes after a Test Hush button push the alarm may be in need of cleaning After cleaning press the Test Hush button If the fault does not clear...

Страница 25: ...o test your plan before an emergency You may not be able to reach your children It is important they know what to do Familiarize everyone with the sounds of the smoke alarm and train them to leave you...

Страница 26: ...t can result in improper operation California State Fire Marshal Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household a...

Страница 27: ...io or television reception the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between...

Страница 28: ...acturer be liable for loss of use of this product or for any indirect special incidental or consequential damages or costs or expenses incurred by the consumer or any other user of this product whethe...

Отзывы: