manualshive.com logo in svg
background image

2-in-1 Smoke and

Carbon Monoxide Alarm

User Guide for Model KN-COSM-B-RF

Smart Wireless Network

    2521-7203-00

For questions concerning your 2-in-1 Smoke and Carbon Monoxide 

Alarm, please call our consumer hotline at 1-800-880-6788. For tips on 

how to protect your home and family, visit www.kidde.com

For your convenience, write down the following information. If you call 

our consumer hotline, these are the first questions you will be asked:

ATTENTION: Please take a few minutes to thoroughly read this 

user guide which should be saved for future reference and 

passed on to any subsequent owner.

Alarm Model Number

(located on back of the alarm):

Date of Manufacture

(located on back of the alarm):

Date of Purchase:

Where Purchased:

Clear Voice Instructions

2521-7203-00_V7b.indd   1

14-2-18   上午11:48

Содержание KN-COSM-B-RF

Страница 1: ...de com For your convenience write down the following information If you call our consumer hotline these are the first questions you will be asked ATTENTION Please take a few minutes to thoroughly read...

Страница 2: ...onoxide Alarm provides you with multiple options Choose the level of protection that is right for you Install as a single unit Install multiple Kidde alarms that connect wirelessly to communicate with...

Страница 3: ...ation 12 15 5 Product Features and Specifications 16 21 6 Installation Guide How to Install 22 Battery Replacement 25 Where to Mount the Alarm 25 29 7 Testing and Using the Alarm 30 Smoke Alarm Silent...

Страница 4: ...kitchen If the alarm sounds check for fires first If a fire is discovered follow these steps Become thoroughly familiar with these steps and review with all family members Alert small children in the...

Страница 5: ...equipment not inspected by the technician and consult the manufacturer s instructions or contact the manufacturer directly for more information about CO safety and the equipment Make sure that motor...

Страница 6: ...d for use in ordinary indoor locations of family living units It is not designed to measure compliance with Occupational Safety and Health Administration OSHA commercial or industrial standards It is...

Страница 7: ...around your home that alert your family to danger This Smart Wireless Network automatically activates all Kidde devices as soon as one alarm is triggered letting everyone know it is time to follow th...

Страница 8: ...fire drill at least every six months including fire drills at night Ensure that small children hear the alarm and wake when it sounds They must wake up in order to execute the escape plan Practice all...

Страница 9: ...ity of individuals in the household who are capable of assisting others to provide assistance to those who may not be awakened by the alarm sound or to those who may be incapable of safely evacuating...

Страница 10: ...otection for those areas separated by a door from the areas protected by the required smoke alarms For this reason it is recommended that the householder consider the use of additional smoke alarms fo...

Страница 11: ...y cases of reported CO poisoning indicate that while victims are aware they are not well they become so disoriented they are unable to save themselves by either exiting the building or calling for ass...

Страница 12: ...ser guide Possible Sources of Carbon Monoxide Inside your home appliances used for heating and cooking are the most likely sources of CO Vehicles running in attached garages can also produce dangerous...

Страница 13: ...ent pipe connections vibrating loose from clothes dryers furnaces or water heaters Obstructions in or unconventional vent pipe designs which can amplify the above situations Extended operation of unve...

Страница 14: ...t does not prevent CO from occurring nor can it solve an existing CO problem If your unit has alarmed and you ve provided ventilation by leaving your windows and doors open the CO buildup may have dis...

Страница 15: ...f CO on one level of the home and a CO alarm installed on a different level For example CO in the basement may not reach an alarm on the second level For these reasons we recommend you provide complet...

Страница 16: ...time to replace the alarm Replace the alarm immediately It will not detect CO in this condition To help identify the date to replace the alarm a space has been designated on the product label affixed...

Страница 17: ...s triggered a wireless signal will be transmitted to activate the rest of your Kidde alarms within 11 seconds alerting you if you are in other parts of the home All other alarms will activate and rema...

Страница 18: ...ce pattern will sound once every minute until the unit is reset or the CO eliminated The red LED will flash while in alarm voice mode LOW BATTERY When the batteries are low and need replacing the red...

Страница 19: ...y two seconds indicates the unit is in smoke alarm Silent Mode See Smoke Alarm Silent Mode Feature section for more details One flash every second indicates Initiating Alarm and one flash every 16 sec...

Страница 20: ...physically or mentally impaired such that they cannot escape even when warned early enough that escape should be possible For these people other strategies such as protection in place or assisted esc...

Страница 21: ...m For maximum protection a smoke alarm should be installed in each sleeping area on every level of a home Although smoke alarms can help save lives by providing an early warning of a fire they are not...

Страница 22: ...be the same for each alarm This ID pattern will differentiate your alarm system from similar systems nearby Do not use the default ID pattern that your units are shipped with 4 Use a pen or pencil to...

Страница 23: ...ot been activated on any of the units it is likely that you are receiving interference from a similar system nearby In this case repeat the above steps and select a different DIP switch pattern Be sur...

Страница 24: ...being installed in the proper sequence Smoke CO alarm will not engage the attachment stud see page 29 unless all three batteries are installed and the battery door is closed Removal of any or all bat...

Страница 25: ...er WARNING Use only the batteries specified Use of different batteries may have a detrimental effect on the smoke CO alarm A good safety measure is to replace the batteries twice a year at the same ti...

Страница 26: ...is listed in Standard 72 Install smoke alarms on sloped peaked or cathedral ceilings at or within 3 ft 0 9 m of the highest point measured horizontally see Diagram A NFPA 72 states Smoke alarms in roo...

Страница 27: ...ASSOCIATION S STANDARD 72 National Fire Protection Association Batterymarch Park Quincy MA 02269 Recommended Locations Diagram A Diagram B Diagram C Installation Guide FIGURE 2 FIGURE 3 FIGURE 1 10 2...

Страница 28: ...tions Do not install in peaks of vaulted ceilings A frame ceilings or gabled roofs see Diagram A on previous page Keep out of damp and humid areas Install at least 1 ft away from fluorescent lights si...

Страница 29: ...al when wall mounting See Figures 1 and 2 3 Drill a hole through the pencil mark and use the enclosed screw and anchor see Figure 1 to secure the attachment stud Use 1 4 0 25 drill bit for anchor hole...

Страница 30: ...ffected the operation of your wireless system Remote Push to Test Test your Kidde alarm system by activating the test button on any Kidde alarm for a minimum of five seconds or until all of the interc...

Страница 31: ...ature has the capability of temporarily desensitizing the smoke alarm circuit for approximately eight minutes This feature is to be used only when a known condition such as smoke from cooking activate...

Страница 32: ...Low Battery Silence period your alarm is performing normally and is not desensitized NOTE Dense smoke will override the smoke alarm Silent Mode feature and sound a continuous alarm CAUTION BEFORE USIN...

Страница 33: ...ce message mentioned above If a CO alarm previously occurred the green LED will flash every 16 seconds Alarm Memory Pushing the test button will clear CO Alarm Memory and initiate the test sequence If...

Страница 34: ...attempt to disassemble the unit or clean inside This action will void your warranty Move the smoke CO alarm and place in another location prior to performing any of the following Staining or stripping...

Страница 35: ...s FCC Compliance Statement This device has been designed constructed and tested for compliance with FCC Rules that regulate intentional and unintentional radiators The user is not permitted to make an...

Страница 36: ...d Remove batteries change the ID and reinstall batteries Check to see if the green LED blinks every 30 seconds This tells you that it is receiving power from the batteries If not make sure the batteri...

Страница 37: ...r limitation of consequential or incidental damages so the above limitations or exclusions may not apply to you Legal Remedies This warranty gives you specific legal rights and you may also have other...