background image

Kidde Fire Systems

400 Main Street

Ashland, MA 01721

Ph: 508.881.2000

Fax: 508.881.8920

www.kiddefiresystems.com

This literature is provided for informational purposes only. KIDDE-FENWAL, INC. believes this data to be accurate, but it is published and presented without any 
guarantee or warranty whatsoever. KIDDE-FENWAL, INC. assumes no responsibility for the product's suitability for a particular application. The fire suppression system 
design, installation, maintenance, service and troubleshooting must be performed by trained, authorized Kidde Fire Systems distributors for the product to work correctly. 
If you need more information on this product, or if you have a particular problem or question, contact:
 KIDDE-FENWAL, INC., Ashland, MA 01721 USA, Telephone: (508) 881-2000.

K-71-101  Rev AA
©2020  

Carrier

Kidde, Fenwal, Chemetron, and SmartOne are registered trademarks of Kidde-Fenwal, Inc., or its parents, subsidiaries or affiliates.

SIGA-LED

Remote Indicator

(OPTIONAL)

+

-

NOTE: Maximum wiring resistance to SIGA-LED

must not exceed 10 Ohms (per wire).

To next detector

From control unit

or

From previous detector

DS-SB Standard Base

(Shown with Class B Wiring and Optional Remote LED)

To next detector

From control unit

or

From previous detector

TERMINAL DESIGNATIONS:

1

Not used

2

SLC IN/OUT

3

Not used

4

SLC IN/OUT

5

Remote LED +

6

Not used

7

Remote LED -

Number

Description

TERMINAL DESIGNATIONS:

1

Normally Open

2

SLC IN/OUT

3

Common

4

SLC IN/OUT

5

Not used

6

Normally Closed

7

Not used

Number

Description

DS-RB Standard Base

(Shown with Class B Wiring)

  EXPORT INFORMATION (USA)

       Jurisdiction: EAR

       US ECCN: EAR99

This document contains technical data subject to the EAR.

Содержание SmartOne KS-PS

Страница 1: ... readings and compares this information to a preprogrammed setting ADDRESSING KS PS detectors feature electronic addressing No addressing switches are used PROTOCOL This product will operate only on a Kidde Fire Systems fire alarm suppression control unit employing SmartOne communications protocol STATUS LED KS PS detectors use an LED to indicate the detector s condition In normal standby conditio...

Страница 2: ...e 24 VDC nominal Current Normal Operating Alarm 150 µA 220 µA SLC Protocol SmartOne UL cUL smoke sensitivity range 0 5 to 3 50 ft 2 95 to 11 48 m obscuration Open Area Use Only NOTE Smoke sensitivity is selected at the control unit or with the remote configuration software Default values are 2 0 ft Alarm and 1 5 ft Pre Alarm Refer to the Installation Operation and Maintenance Manual or the Configu...

Страница 3: ... wire loops will be wired as shown bringing loose end of loop back to the control unit COMPATIBLE CONTROL UNITS FACUs running software revision 82 4 are compatibility tested but not agency listed with the device s in this data sheet Fire Alarm Control Unit FACU Type Current Product Legacy Product Single Loop ARIES SLX ARIES FenwalNET 6000 MICRO SLX PEGAsys FenwalNET 2000 Multiple Loop ARIES MLX AR...

Страница 4: ... Ashland MA 01721 USA Telephone 508 881 2000 K 71 101 Rev AA 2020 Carrier Kidde Fenwal Chemetron and SmartOne are registered trademarks of Kidde Fenwal Inc or its parents subsidiaries or affiliates SIGA LED Remote Indicator OPTIONAL NOTE Maximum wiring resistance to SIGA LED must not exceed 10 Ohms per wire To next detector From control unit or From previous detector DS SB Standard Base Shown with...

Отзывы: