DETECTOR BASES

The KS-PS detector head attaches easily to these compatible
bases. Detector bases have wiring terminals that are accessible
from the “room-side” after mounting the base to the electrical
box. A trim ring is supplied with the 4-inch base to help hide sur-
face imperfections.

Model DS-SB Standard Base:  

Connects the detector to

the Signaling Line Circuit (SLC).

Model DS-RB Relay Base:  

Connects the detector to the

Signaling Line Circuit (SLC) and provides optional Relay
functionality to the KS-PS detector.

ORDERING INFORMATION

TECHNICAL SPECIFICATIONS

KS-PS

Intelligent Photoelectric Smoke Detector, 
head only

DS-SB

Detector Mounting Base, 4 in. diameter, 
with 6 in. trim ring, for 2-wire connection to 
SmartOne SLC 

DS-RB

Detector Mounting Base, 4 in. diameter, 
with relay option and 6 in. trim ring, for 2-
wire connection to SmartOne SLC 

SM200-12PKG

Canned smoke for functional testing of 
smoke detectors, package of 12

SIGA-LED

Optional Remote Alarm LED

SIGA-VA

Detector Vacuum Attachment

SIGA-RTA

Detector Removal Tool Attachment

Operating voltage

24 VDC (nominal)

Current

Normal Operating
Alarm 

150 µA
220 µA

SLC Protocol

SmartOne

UL/cUL smoke 
sensitivity range

0.5 to 3.50 %/ft. (2.95 to 11.48%/m) 
obscuration 
(Open Area Use Only)

NOTE: 
Smoke sensitivity is selected at the control unit or with the 
remote configuration software. Default values are 2.0%/ft 
(Alarm) and 1.5%/ft (Pre-Alarm). Refer to the Installation, 
Operation and Maintenance Manual  or the Configuration 
Software User Guide for your system.

North American 
standards

UL 268 (7th edition), UL 268A,        
CAN/ULC-S529, FM Approvals 3210     

Compliances:

 

This device complies with Part 15, Class A of the FCC Rules.

Operation is subject to the following two conditions:  (1) This
device may not cause harmful interference, and (2) this device 
must accept any interference received, including interference
that may cause undesired operation.

ICES-003, Class A

EN 55011, Class A

AS/NZS CISPR 11, Class A

Air velocity

0 to 4,000 ft./min (0 to 20.32 m/s)

Compatible bases

DS-SB (Standard), DS-RB (Relay)

Wall mounting: 
distance from ceiling

 12 in. (305 mm) max.

Operating Environment
  Temperature
  Relative humidity

32 to 120°F (0 to 49°C)
0 to 93% non-condensing 

Storage temperature

4 to 140°F (

20 to 60°C)

Environmental 
compensation

Automatic

Color

White head and base

Construction

High impact engineering polymer

Mounting

Plug-in

Содержание SmartOne KS-PS

Страница 1: ... readings and compares this information to a preprogrammed setting ADDRESSING KS PS detectors feature electronic addressing No addressing switches are used PROTOCOL This product will operate only on a Kidde Fire Systems fire alarm suppression control unit employing SmartOne communications protocol STATUS LED KS PS detectors use an LED to indicate the detector s condition In normal standby conditio...

Страница 2: ...e 24 VDC nominal Current Normal Operating Alarm 150 µA 220 µA SLC Protocol SmartOne UL cUL smoke sensitivity range 0 5 to 3 50 ft 2 95 to 11 48 m obscuration Open Area Use Only NOTE Smoke sensitivity is selected at the control unit or with the remote configuration software Default values are 2 0 ft Alarm and 1 5 ft Pre Alarm Refer to the Installation Operation and Maintenance Manual or the Configu...

Страница 3: ... wire loops will be wired as shown bringing loose end of loop back to the control unit COMPATIBLE CONTROL UNITS FACUs running software revision 82 4 are compatibility tested but not agency listed with the device s in this data sheet Fire Alarm Control Unit FACU Type Current Product Legacy Product Single Loop ARIES SLX ARIES FenwalNET 6000 MICRO SLX PEGAsys FenwalNET 2000 Multiple Loop ARIES MLX AR...

Страница 4: ... Ashland MA 01721 USA Telephone 508 881 2000 K 71 101 Rev AA 2020 Carrier Kidde Fenwal Chemetron and SmartOne are registered trademarks of Kidde Fenwal Inc or its parents subsidiaries or affiliates SIGA LED Remote Indicator OPTIONAL NOTE Maximum wiring resistance to SIGA LED must not exceed 10 Ohms per wire To next detector From control unit or From previous detector DS SB Standard Base Shown with...

Отзывы: