background image

ASSEMBLY INSTRUCTIONS

DRIVE

IO module

IO module smart

SIEGENIA access control 

systems

Comfort systems

Door systems

Window systems

Содержание SIEGENIA DRIVE IO module

Страница 1: ...ASSEMBLY INSTRUCTIONS DRIVE IO module IO module smart SIEGENIA access control systems Comfort systems Door systems Window systems ...

Страница 2: ......

Страница 3: ...D OPERATING ELEMENTS 9 7 1 12 pin connection terminal strip 9 7 2 Termination 10 8 INSTALLATION 10 9 CABLE DIAGRAMS 11 9 1 IO module IO module smart in slave mode 11 9 2 Plug and play cable routing with frame integrated power supply 13 9 2 1 Connect KFV drive to cable transition 13 9 2 2 Connect cable transition to frame integrated power supply 14 9 2 3 Connect frame integrated power supply to IO ...

Страница 4: ...c The IO module IO module smart is intended for indoor use IP20 with a room temperature of 0 C to 45 C and is either installed in suitable flush mount ed boxes or surface mounted in approved branch boxes All assembly and electrical installation work must be carried out according to our assembly instructions Use the IO module IO module smart only when it is in a technically sound condition Repair o...

Страница 5: ...observed provide protection against potential personal injury and material damage classify the level of danger by the signal word designate the danger of personal injury via the hazard sign define the type and source of danger show measures to prevent hazards and prohibit specific behaviour The warning notes are set up according to the following principle SIGNAL WORD Type and source of danger expl...

Страница 6: ... Two potential free input contacts e g for intercom system provided by customer and for day night switchover via timer Online remote access via REMOTE access Online user administration Online PUSH notification Communication via SI BUS Secure encrypted communication via AES 128 Bit Update option via SI BUS for online access via an internet capable WIFI router 2 3 Warning notes DANGER Risk of fatal ...

Страница 7: ...en closed feedback in case of active error feedback in case of voltage on feedback in case of latch drawn Function allocation of the inputs open opening impulse switchover day night mode combination day night mode opening via im pulse control Silent mode 4 4 A opener With the IO module IO module smart the A opener can be extended by the following inputs and outputs function allocation of the outpu...

Страница 8: ... continue to be used unrestrictedly A opener GENIUS A GENIUS B A SI Bus Siemensstr 10 D 42551 Velbert GEN 2 2 B SN R1 R2 R3 24V DC 24V DC Input Output B C D 0 1 2 3 4 7 A SI Bus Siemensstr 10 D 42551 Velbert A OPENER 2 2 SN R1 R2 R3 24V DC GND 24V DC GND Input B C D 2 3 4 A SI Bus Siemensstr 10 D 42551 Velbert GEN 2 2 A SN R1 R2 R3 24V DC 24V DC Input n c B C D 0 1 2 3 4 7 n c n c SI BUS Analogue ...

Страница 9: ...rminal strip for inputs and outputs 24 V DC 2 Status LED 3 Menu LED 4 WIFI LED only for IO WIFI module 5 Connection sockets for SI BUS connection 6 Menu navigation button 7 1 12 pin connection terminal strip Connection for Function 1 2 Potential free input contact 1 3 4 Potential free input contact 2 5 6 Potential free output contact 1 7 8 Potential free output contact 2 9 10 Potential free output...

Страница 10: ...ermination of the SI BUS system insert the JST termination plug 1 included in the delivery into a free SI Bus bushing 8 Installation The IO module is suitable both for flush mounting and surface mounting f f Break off the two brackets for flush mounting f f Mount the module in a flush mounting box f f Use the two brackets for surface mounting ...

Страница 11: ... digitally via the SI BUS log with the electromechanical drive of the KFV multi point lock The drive A opener GENIUS A B PANIC takes over the master functions and the IO module IO module smart is operated in slave mode Max 3 SIEGENIA ACS and up to 7 IO modules can be integrated into a BUS system The last slave component must terminate the SI BUS system via a termination plug included in delivery o...

Страница 12: ...0EN 00 IO module IO module smart with top hat rail power supply 1 5 4 3 2 Item Name 1 Electromechanical KFV drive A opener GENIUS A GENIUS B GENIUS PANIC 2 Cable transfer 3 Top hat rail power supply termination via cable 4 IO module IO module smart 5 Inputs outputs for external devices e g intercom system ...

Страница 13: ... R1 R2 R3 24V DC 24V DC Input Output B C D 0 1 2 3 4 7 1 A SI Bus Siemensstr 10 D 42551 Velbert GENIUS B SN R1 R2 R3 24V DC 24V DC Input Output B C D 0 1 2 3 4 7 f f Insert the green PTR plug 1 of the adapter cable into the connection of the A opener GENIUS drive with the marking SI BUS A to D 2 1 3 4 5 f f Connect the bushing 1 of the adapter cable with the plug 2 of the extension cable f f Conne...

Страница 14: ...the adapter cable into the con nection GENIUS A opener side 0 to 3 of the power supply 4 9 2 3 Connect frame integrated power supply to IO module IO module smart 1 3 4 7 2 6 5 f f Insert the green PTR plug 1 of the adapter cable into the connection optional side 0 to 3 of the power supply 2 f f Insert the plug 3 of the adapter cable on the bushing 4 of the extension cable and the bushing 5 into th...

Страница 15: ...1 R2 R3 24V DC 24V DC Input Output B C D 0 1 2 3 4 7 1 A SI Bus Siemensstr 10 D 42551 Velbert GENIUS B SN R1 R2 R3 24V DC 24V DC Input Output B C D 0 1 2 3 4 7 f f Insert the green PTR plug 1 of the adapter cable into the connection of the A opener GENIUS drive with the marking SI BUS A to D 2 1 3 4 5 f f Connect the bushing 1 of the adapter cable with the plug 2 of the extension cable f f Connect...

Страница 16: ...5 2 14A DC OK V V V V V ADJ Ein Unternehmen der SIEGENIA GRUPPE L N Schutzleiter PE Abschirmung anschliessen Connect Shield Earth Connection PE 2 1 3 4 Class 2 output Art No 3509884 100 240VAC 24 28VDC 2 5 2 14A DC OK V V V V V ADJ Ein Unternehmen der SIEGENIA GRUPPE L N Schutzleiter PE Abschirmung anschliessen Connect Shield Earth Connection PE f f Connect the bushing 1 of the adapter cable of th...

Страница 17: ... 240VAC 24 28VDC 2 5 2 14A DC OK V V V V V ADJ Ein Unternehmen der SIEGENIA GRUPPE L N Schutzleiter PE Abschirmung anschliessen Connect Shield Earth Connection PE 1 2 4 3 Class 2 output Art No 3509884 100 240VAC 24 28VDC 2 5 2 14A DC OK V V V V V ADJ Ein Unternehmen der SIEGENIA GRUPPE L N Schutzleiter PE Abschirmung anschliessen Connect Shield Earth Connection PE 1 2 4 3 Item Name 1 SIEGENIA ACS ...

Страница 18: ...nschliessen Connect Shield Earth Connection PE 2 1 3 Class 2 output Art No 3509884 100 240VAC 24 28VDC 2 5 2 14A DC OK V V V V V ADJ Ein Unternehmen der SIEGENIA GRUPPE L N Schutzleiter PE Abschirmung anschliessen Connect Shield Earth Connection PE 2 1 3 Item Name 1 IO module smart 2 Top hat rail power supply for connection via 12 pin terminal strip Top hat rail power supply connection IO module c...

Страница 19: ...f f For the A opener press the menu button briefly or for the GENIUS hold down the button for approx 8 seconds until the menu magenta LED lights up f f An acoustic signal sounds as acknowledgement A SI Bus Siemensstr 10 D 42551 Velbert A OPENER 2 2 SN R1 R2 R3 24V DC GND 24V DC GND Input B C D 2 3 4 short short f f Keep pressing the menu button until the LED lights up in light red f f Every press ...

Страница 20: ... up magenta f f The devices are coupled 11 Coupling IO module IO module smart with SIEGENIA ACS Both devices must be coupled to use the IO module IO module smart in conjunction with a SIEGENIA ACS f f The menu LED must light up magenta f f If the menu LED on the IO mod ule does not light up magen ta press the button briefly to switch on the LED f f When the menu LED lights up magenta press the but...

Страница 21: ...nal 10x is audible on the access control system and green is displayed f f The devices are coupled 12 Rectification of malfunctions In case of a malfunction do not open the device or try to repair it under any circumstances Note you will find detailed information on how to rectify malfunctions on the SIEGENIA Smarthome Internet page https smarthome siegenia com If the Internet age dies not describ...

Страница 22: ...rectives about electrical and electronic products The following listed test standards which are harmonised in the relevant directives have been employed for the evaluation a 2014 30 EU EMC Directive EN 301 489 1 V1 9 2 EN 301 489 17 V2 2 1 EN 61000 3 2 2014 EN 61000 3 3 2013 EN 61000 6 1 2007 EN 61000 6 2 2005 Part EN 61000 6 3 2007 A1 2011 b 2014 35 EU Low Voltage Directive DIN EN 60730 1 2012 10...

Страница 23: ......

Страница 24: ...www siegenia com H39 ELEKS010EN 00 ...

Отзывы: