„Installation and operation manual for fireplace insert”
28
Table 5. Norms and regulations.
Regulation of the Minister of Infrastructure of 12 April 2002 on technical conditions to be met by buildings and
their situation (
Journal of Laws № 75, item 690)
Regulation of the Minister of Infrastructure of 7 April 2004 amending the regulation on technical conditions to be
met by buildings and their situation
Regulation of the Minister of Infrastructure of 6 November 2008 amending the regulation on technical conditions
to be met by buildings and their situation
Regulation of the Minister of Infrastructure of 12 March 2009 amending the regulation on technical conditions to
be met by buildings and their situation
PN-89/B-10425 Flues, exhaust gas ducts and brick ventilation ducts
– Technical requirements and inspection
upon acceptance
PN-EN 13229 Fireplace inserts with open solid fuel fireplaces. Requirements and tests, December 2002
AMENDMENT TO THE POLISH NORM PN-EN 13229:2002/A1 March 2005
AMENDMENT TO THE POLISH NORM PN-EN 13229:2002/A2 June 2006
PN-EN 1443: 2001 Chimneys. General requirements.
PN-EN 1443: 2005 Chimneys. General requirements.
PN
–87/B-02411 Integrated solid fuel boiler rooms.
PN-91/B-02413 Heating and heat engineering. Protection of water heating installations of the open system.
All the operations recommendations and tips contained in this manual ought to be
checked against local regulations respectively!!!
6 Parameters of KFD ECO
KFD EKO
MAX 7 L/R
KFD EKO
MAX 14
KFD EKO
MAX 7 3F
KFD EKO
M 7
energy efficiency class
A+
A+
A+
A+
direct heat output (nominal power)
[kW]
11,5
11,5
11,5
11,5
heating power range
[kW]
6 - 15
6 - 15
6 - 15
6 - 15
energy efficiency index
[EEI]
110,6
110,6
110,6
110,6
energy efficiency at nominal heat output
[%]
82,5
82,5
82,5
82,5
seasonal space heating energy efficiency
[%]
73,5
73,5
73,5
73,5
CO emission at 13% O2
[%]
0,09
0,09
0,09
0,09
[mg/Nm3]
1162
1162
1162
1162
dust emission at 13% O2
[mg/Nm3]
19
19
19
19
OGC at 13% O2
[mg/Nm3]
51
51
51
51
NOX emission at 13% O2
[mg/Nm3]
145
145
145
145
flue gas mass flow
[g/s]
9,75
9,75
9,75
9,75
verage smoke temperature at smoke outlet
[°C]
235
235
235
235
minimum chimney draft
[Pa]
12
12
12
12
weight
[kg]
115
115
115
110
Содержание ECO MAX 7 R
Страница 29: ... Installation and operation manual for fireplace insert 29 KFD EKO MAX 14 KFD EKO MAX 7 L R basic ...
Страница 30: ... Installation and operation manual for fireplace insert 30 KFD EKO MAX 7 L R standard KFD EKO MAX 7 3F basic ...
Страница 31: ... Installation and operation manual for fireplace insert 31 KFD EKO MAX 7 3F standard KFD EKO M 7 ...
Страница 35: ... Installation and operation manual for fireplace insert 35 Date Performed work Company Signature ...