![Keysight U4421A Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/keysight/u4421a/u4421a_hardware-and-probing-manual_1961143029.webp)
Keysight U4421A MIPI D-PHY Analyzer and Exerciser Hardware and Probing Guide
29
Setting up an E5381A Differential Flying Lead Probe Configuration for U4421A Module
4
Based on the number assigned to each flying lead (see
), the following table lists which flying
lead of the probe to be used to probe different D-PHY signals.
Signal to be probed
Flying Lead to be used
Notes/Usage of flying lead
Clkp
Ch 13
Connect the Positive (Light grey) cable of the flying lead to acquire signal.
Connect the Negative (Dark grey) cable of the flying lead to ground.
Clkn
Ch 15
Connect the Positive (Light grey) cable of the flying lead to acquire signal.
Connect the Negative (Dark grey) cable of the flying lead to ground.
Clk diff
Ch 14
Connect the Positive (Light grey) cable of the flying lead to the Clkp signal and
Negative (Dark grey) cable of the flying lead to the Clkn signal.
Data Lane 0 p
Ch 0
Connect the Positive (Light grey) cable of the flying lead to acquire signal.
Connect the Negative (Dark grey) cable of the flying lead to ground.
Data Lane 0 n
Ch 2
Connect the Positive (Light grey) cable of the flying lead to acquire signal.
Connect the Negative (Dark grey) cable of the flying lead to ground.
Data Lane 0 diff
Ch 1
Probe differentially
Connect the Positive (Light grey) cable of the flying lead to the D0p signal and
Negative (Dark grey) cable of the flying lead to the D0n signal.
Data Lane 1
Ch 4
Probe differentially
Connect the Positive (Light grey) cable of the flying lead to the D1p signal and
Negative (Dark grey) cable of the flying lead to the D1n signal.
Data Lane 2
Ch 8
Probe differentially
Connect the Positive (Light grey) cable of the flying lead to the D2p signal and
Negative (Dark grey) cable of the flying lead to the D2n signal.
Data Lane 3
Ch 11
Probe differentially
Connect the Positive (Light grey) cable of the flying lead to the D3p signal and
Negative (Dark grey) cable of the flying lead to the D3n signal.
NOTE
The Data Lane 0p, Data Lane 0n, Clkp, and Clkn signals are probed both as
single-ended and differential. This is done to allow the U4421A module to detect
LP and HS modes. When probed as single-ended, you must connect the
negative sides of the single-ended connections to ground.
The Data Lane 1, 2, and 3 each are probed differentially using a single channel
per data lane used.
The U4421A module can capture LP data and display it in "raw" mode on these
data lanes. If you want to capture LP data on these lanes, then you must probe
these lanes single-ended using the following signal to probe’s channel mapping:
D1p - Ch 3
D1n - Ch 5
D2p - Clk
D2n - Ch 9
D3p - Ch 10
D3n - Ch 12