background image

Installation Note

Keysight Add 

Source and Receiver 

Attenuators 

Upgrade Kit

To Upgrade PNA N5224A/B or N5225A/B Option 401 to Option 417 or 
PNA-X N5244A/B or N5245A/B Option 401 to Option 417

For Analyzers with Serial Numbers Prefixed MY/SG/US5150 and Below
Upgrade Kit Order Numbers: N5224AU-417, N5225AU-417, 
N5224BU-417, N5225BU-417, N5244AU-417, N5245AU-417, 
N5244BU-417, and N5245BU-417

Keysight Kit Number: 

N5225-6010

7

Содержание N5225-60107

Страница 1: ...A B Option 401 to Option 417 or PNA X N5244A B or N5245A B Option 401 to Option 417 For Analyzers with Serial Numbers Prefixed MY SG US5150 and Below Upgrade Kit Order Numbers N5224AU 417 N5225AU 417...

Страница 2: ...ftware to U S government customers under its standard commercial license which is embodied in its End User License Agreement EULA a copy of which can be found at http www keysight com find sweula The...

Страница 3: ...ont panel overlay replacement new cables After installation of this upgrade your analyzer will be an N5224A B Option 417 or N5225A B Option 417 or N5244B Option 417 or N5245B Option 417 Some of the as...

Страница 4: ...ght com find assist If you do not have access to the Internet please contact your Keysight field engineer If You Have Problems With the Upgrade Kit Contents Keysight stands behind the quality of the u...

Страница 5: ...ols Required for the Installation on page 6 Enough time refer to About Installing the Upgrade on page 6 Test equipment for the post upgrade adjustments and full instrument calibration To view the equi...

Страница 6: ...NA To find your new HostID go to http www na support keysight com pna upgrades html and using the HostID utility enter the PNA serial number and your new upgraded PNA X model number N5224A N5225A N524...

Страница 7: ...ssistance Refer to Getting Assistance from Keysight on page 3 Downloading the Online PNA Service Guide To view the online Service Guide for your PNA model number use the following steps 1 Go to www ke...

Страница 8: ...bs 2 38 N m 1 N A 5 16 in 8 mm nutsetter or open end torque wrench set to 10 in lbs 1 13 N m 1 N A Use a 5 16 in torque wrench set to 10 in lbs on all cable connections Products affected N5224A B N522...

Страница 9: ...wer Front panel overlay PNA B models N5224 5B 1 N5225 80006 Lower Front panel overlays PNA X models N5244 5B 1 N5242 80031 Machine screw M3 x 8 pan head to attach brackets to attenuators to attach por...

Страница 10: ...3 receiver attenuator to A28 mixer brick C 1 N5245 20066 W101 RF cable front panel Port 4 RCVR D IN to A48 port 4 receiver attenuator 1 N5245 20074 W102 RF cable A48 port 4 receiver attenuator to A28...

Страница 11: ...Assemblies Step 8 Assemble the Source Attenuator Assemblies Step 9 Install the Source Attenuator Assemblies Step 10 Install Some Bottom Side Test Set Cables Step 11 Remove the Old Lower Front Panel Ov...

Страница 12: ...ter Cover For instructions click the Chapter 7 bookmark Removing the Covers in the PDF Service Guide Step 3 Remove Some Bottom Side Test Set Cables 1 Place the analyzer bottom side up on a flat surfac...

Страница 13: ...st port 2 receiver coupler to front panel Port 2 SOURCE OUT W33 N5245 20108 A32 port 2 receiver coupler to front panel REF 2 SOURCE OUT W37 N5245 20041 Front panel Port 1 RCVR A IN to A27 mixer brick...

Страница 14: ...r this step of the procedure New parts are listed in Table 1 on page 7 Use a T 10 TORX driver to tighten all screws Figure 1 Port 1 and Port 2 Receiver Attenuator and Bracket Assembly Step 5 Install t...

Страница 15: ...the Upgrade Figure 2 Port 1 and Port 2 Receiver Attenuator Assemblies Installation Step 6 Assemble the Port 3 and Port 4 Receiver Attenuator Assemblies Refer to Figure 3 for this step of the procedure...

Страница 16: ...r the Upgrade Figure 3 Port 3 and Port 4 Receiver Attenuator and Bracket Assembly Step 7 Install the Port 3 and Port 4 Receiver Attenuator Assemblies Refer to Figure 4 for this step of the procedure N...

Страница 17: ...Installation Note N5225 90107 15 Description of the Upgrade Installation Procedure for the Upgrade Figure 4 Port 3 and Port 4 Receiver Attenuator Assemblies Installation...

Страница 18: ...lation Procedure for the Upgrade Step 8 Assemble the Source Attenuator Assemblies Refer to Figure 5 for this step of the procedure New parts are listed in Table 1 on page 7 Use a T 10 TORX driver to t...

Страница 19: ...llation Procedure for the Upgrade Step 9 Install the Source Attenuator Assemblies Refer to Figure 6 for this step of the procedure New parts are listed in Table 1 on page 7 Use a T 10 TORX driver to t...

Страница 20: ...rvice Guide1 New parts are listed in Table 1 on page 7 Install the following new cables in the order listed W103 N5245 20055 Port 2 RCVR B IN to A49 port 2 receiver attenuator W94 N5245 20031 A41 port...

Страница 21: ...A27 mixer brick R2 W101 N5245 20074 Port 4 RCVR D IN to A48 port 4 receiver attenuator W45 reuse N5245 20021 REF 4 RCVR R4 IN to 3 dB pad on A28 mixer brick R4 W90 N5245 20028 A40 port 4 source attenu...

Страница 22: ...31 port 4 receiver coupler to A40 port 4 source attenuator W99 N5245 20073 Port 3 RCVR C IN to A47 port 3 receiver attenuator W86 N5245 20027 A39 port 3 source attenuator to front panel Port 3 SOURCE...

Страница 23: ...o W13 W16 reuse N5245 20044 A31 port 4 receiver coupler to W15 W97 N5245 20054 Front panel Port 1 RCVR A IN to A46 port 1 receiver attenuator W82 N5245 20077 A38 port 1 source attenuator to front pane...

Страница 24: ...029 A32 port 2 receiver coupler to A41 port 2 source attenuator Install the Ribbon Cables To see an image showing the location of these cables click the Chapter 6 bookmarks Bottom Ribbon Cables and Wi...

Страница 25: ...test set motherboard J546 N5245 60026 A46 port 1 receiver step attenuator to A23 test set motherboard J205 N5245 60026 A47 port 3 receiver step attenuator to A23 test set motherboard J206 N5245 60007...

Страница 26: ...e front panel use a blunt object in the cutouts in the lower front dress panel to push on the old overlay item and separate it from the front dress panel 2 From the front side of the front panel pull...

Страница 27: ...Installation Note N5225 90107 25 Description of the Upgrade Installation Procedure for the Upgrade Figure 11 Lower Front Panel Overlay Replacement...

Страница 28: ...item 2 Starting from either side loosely place the overlay in the recess on the lower front panel ensuring that it fits tightly against the edges of the recess 3 Once the overlay is in place press it...

Страница 29: ...enable utility press UTILITY then then An option enable dialog box will appear 2 Click the arrow in the Select Desired Option box A list of available options will appear 3 In the Select Desired Option...

Страница 30: ...Option Enable Procedure for B Model Instruments on page 29 Option Enable Procedure for A Model Instruments 1 To start the option enable utility press UTILITY then then An option enable dialog box will...

Страница 31: ...For these steps refer to the example in Figure 12 on page 30 a Verify your USB flash drive is connected to a PC b Open your license file using a text read write program similar to Notepad c If you hav...

Страница 32: ...e Else load the license key file s manually move your license file s to C Program Files Agilent licensing It may take Keysight License Manager an extra 5 seconds to enable the licenses 5 Disconnect th...

Страница 33: ...ain adjustment receiver characterization receiver adjustment IF Response adjustment For A model Options 090 093 or 094 Only For B models Options S93090xA B S93093A B or S93094A B Only Noise adjustment...

Страница 34: ...you experience difficulty with the basic functioning of the analyzer contact Keysight Refer to Contacting Keysight on page 2 Calibration Although the analyzer functions its performance relative to it...

Страница 35: ...20 Prepare the PNA for the User 1 If necessary reinstall front jumper cables 2 Install the cable guards pushing them over the front jumper cables until the cushioning material touches the front panel...

Страница 36: ...This information is subject to change without notice Keysight Technologies 2011 2019 Edition 2 June 2019 N5225 90107 www keysight com...

Отзывы: