background image

Safety Symbols

A CAUTION denotes a hazard. It 

calls attention to an operating pro-

cedure or practice, that, if not cor-

rectly performed or adhered to 

could result in damage to the 

product or loss of important data. 

Do not proceed beyond a CAUTION 

notice until the indicated condi-

tions are fully understood and met.

A WARNING denotes a hazard. It 

calls attention to an operating pro-

cedure or practice, that, if not cor-

rectly performed or adhered to, 

could result in personal injury or 

death. Do not proceed beyond a 

WARNING notice until the indi-

cated conditions are fully under-

stood and met. 

Products display the following sym-

bols:

The instrument has been tested, 

investigated and found to comply with 

the requirements of the Standard(s) for 

Electrical Measuring & Test Equip-

ment.

Notice for European Community: This 

product complies with the relevant 

European legal Directives: EMC Direc-

tive (2004/108/EC) and Low Voltage 

Directive (2006/95/EC).

This is the symbol for an Industrial, 

Scientific, and Medical Group 1 Class A 

product.

The Regulatory Compliance Mark 

(RCM) mark is a registered trademark. 

This signifies compliance with the Aus-

tralia EMC Framework regulations 

under the terms of the Radio Commu-

nication Act of 1992.

ICES/NMB-001 indicates that this ISM 

device complies with the Canadian 

ICES-001.

This symbol represents the time period 

during which no hazardous or toxic 

substance elements are expected to 

leak or deteriorate during normal use. 

Forty years is the expected useful life 

of this product.

 

Waste Electrical and 

Electronic 

Equipment (WEEE) 

Directive               

2002/96/EC

This product complies with the WEEE 

Directive (2002/96/EC) marking 

requirement. The affixed product label 

(see below) indicates that you must not 

discard this electrical/electronic prod-

uct in domestic household waste.

Product Category: With reference to 

the equipment types in the WEEE 

directive Annex 1, this product is clas-

sified as a “Monitoring and Control 

instrumentation” product.
Do not dispose in domestic household 

waste.
To return unwanted products, contact 

your local Keysight office, or see 

www.keysight.com/environment/prod-

uct  

for more information. 

Warning, risk of electric 

shock

Refer to manual for addi-

tional safety information.

Earth Ground.

Chassis Ground.

Alternating Current (AC).

Standby Power. Unit is not 

completely disconnected 

from AC mains when 

switch is in standby.
Antistatic precautions 

should be taken.

For localized Safety Warnings, Refer 

to Keysight Safety document (p/n 

9320-6792).

ICES/NMB-001

ISM GRP 1-A

 

v

Содержание M9187A

Страница 1: ...Keysight M9187A PXI Digital IO Module Startup Guide...

Страница 2: ......

Страница 3: ...NOTICE IN FUTURE EDI TIONS FURTHER TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW KEYSIGHT DISCLAIMS ALL WAR RANTIES EITHER EXPRESS OR IMPLIED WITH REGARD TO THIS MANUAL AND ANY INFORMATION CONTAIN...

Страница 4: ...erform proce dures involving cover or shield removal unless you are qualified to do so DO NOT operate damaged equipment Whenever it is possible that the safety protection features built into this prod...

Страница 5: ...k regulations under the terms of the Radio Commu nication Act of 1992 ICES NMB 001 indicates that this ISM device complies with the Canadian ICES 001 This symbol represents the time period during whic...

Страница 6: ...vi...

Страница 7: ...ep 4 Connect the Controller to the PXI Chassis 16 Using a remote PC 16 Using an embedded computer 16 Step 5 Install the Module in the PXI Chassis 17 Step 6 Verify Operation of the Module 19 Run Keysig...

Страница 8: ...viii Keysight M9187A PXI Digital IO Module Startup Guide...

Страница 9: ...puts can be connected directly to the outputs without risk of damage allowing module configuration for operation as 32 channels of independent input and output or as 32 channels of configurable I O Us...

Страница 10: ...t and heel strap combination Both types when used together provide a significant level of ESD protection Of the two only the table mat and wrist strap combination provides adequate ESD protection when...

Страница 11: ...Support information on the product web page at www keysight com find pxi dio 3 Write the following information on a tag and attach it to the malfunctioning equipment Name and address of owner A Post O...

Страница 12: ...Keysight IO Libraries Suite version 16 0 or later Any other accessories that you ordered cables connectors etc Step 3 Install the Software on the Host Computer The following illustration shows typical...

Страница 13: ...ncludes 1GB available for Microsoft NET Framework 3 5 SP1 100MB for Keysight IO Libraries Suite 1 5 GB available hard disk space includes 1GB available for Microsoft NET Framework 3 5 SP12 100MB for K...

Страница 14: ...Expert the IVI Shared Components and the VISA Shared Components 1 Insert the Automation Ready CD with Keysight IO Libraries Suite into the CD ROM drive of your system controller Wait a few seconds fo...

Страница 15: ...Microsoft development environments e g Visual Studio C C C Visual Basic Keysight VEE MATLAB or National Instruments Labview Accept the license terms and click Next Keysight Software License Agreement...

Страница 16: ...top With a Keysight Y1200A cable connect the adapter to the System Interface module on the PXI chassis Using an embedded computer Refer to the figure above If you are using an embedded controller in t...

Страница 17: ...lacing the module card edges into the front module guides top and bottom Slide the module to the rear of the chassis and assure that the injector ejector handle is pushed down in the unlatched downwar...

Страница 18: ...or laptop PC power on the computer Choose the default option for any Found New Hardware dialogs Chassis Power Down Process If you are using a remote controller linked to the M9021A Cable Interface yo...

Страница 19: ...xpert Locate your interfaces and instruments in the Keysight Connection Expert Explorer Pane The following graphic shows the Connection Expert screen Select the module in the center pane Instrument I...

Страница 20: ...Allow Control check box upper left corner before you can actually set the digital output channels If Allow Control is not checked the Output Channels section of the SFP display is grayed out Selectin...

Страница 21: ...to the single slot 3U form factor 100mm by 160mm 3 94 in by 6 3 in Eurocard standard These modules meet PXI Specification 2 2 Local bus trigger bus and star trigger are not included The modules also...

Страница 22: ...h Side driver device The outputs can also be tri stated off For serial input the module s 32 input channels are attenuated then multiplexed through an analog multiplexer A programmable threshold detec...

Страница 23: ...4 shows the M9187A front panel connector as viewed from the module front panel and connector pinout Table 1 on page 25 lists the front panel pin out connections by signal channel number Figure 3 shows...

Страница 24: ...utput 20 45 Output 19 26 Output 18 6 Output 17 66 Output 24 46 Output 23 27 Output 22 7 Output 21 67 Output 28 47 Output 27 28 Output 26 8 Output 25 68 Output 32 48 Output 31 29 Output 30 9 Output 29...

Страница 25: ...37 Input 27 56 Input 28 76 Input 29 18 Input 30 38 Input 31 57 Input 32 77 Output 1 2 Output 2 22 Output 3 41 Output 4 61 Output 5 3 Output 6 23 Output 7 42 Output 8 62 Output 9 4 Output 10 24 Output...

Страница 26: ...for the screw terminals is 0 12 0 15 Nm The following diagram shows the pinout of the connector block The pin numbers match the pin numbers on the module s front panel connector Refer to Disassemblin...

Страница 27: ...pper tin 26AWG with a 3A current rating Nominal resistance is 0 2 M The Y1187A is 1m long and the Y1188A is 2m long Figure 5 Y1187A Y1188A 78 Pin Male to Female Connector Cable Voltages greater than 6...

Страница 28: ...the strain relief bar Refer to Figure 7 4 Insert your cable under the strain relief bar and retighten the two strain relief screws 5 To reassemble the clamshell make certain the screw locks are in pl...

Страница 29: ...non condensing humidity The maximum humidity is 95 at 40 C Do not use in locations where conductive dust or electrolytic salt dust may be present These modules should be operated in an indoor environ...

Страница 30: ...30 Keysight M9187A PXI Digital IO Startup Guide Electrical Operating Conditions...

Страница 31: ...tems Keysight is a founding member of the LXI consortium www pxisa org PCI eXtensions for Instrumentation PXI modular instrumentation delivers a rugged PC based high performance measurement and automa...

Страница 32: ...This information is subject to change without notice Keysight Technologies 2014 Edition 3 December 2014 M9187 90001 M9187 90001 www keysight com...

Отзывы: