background image

Demonstration Guide

Keysight Technologies

N9342C/N9343C/N9344C HSA

Handheld Spectrum Analyzer

Содержание HSA N9342C

Страница 1: ...Demonstration Guide Keysight Technologies N9342C N9343C N9344C HSA Handheld Spectrum Analyzer...

Страница 2: ...e 8 Save recall and the unique User key 9 GPS 10 Task planner 11 Spectrum monitoring and interference hunting 17 Remote control via LAN or USB port 18 Marker marker table and peak table 18 Advance mar...

Страница 3: ...rred to as N934xC HSAs in this document Demonstrated features include Panel tour Auto brightness and back lit keys Save recall and the unique User key GPS Task planner Spectrum monitoring and interfer...

Страница 4: ...ir signals A bandpass filter Demonstration Preparation This demonstration provides the step by step instructions for using the extensive features of N934xC HSAs All demonstration key strokes surrounde...

Страница 5: ...configuration 6 Peak Marker Activates the peak search or marker function 7 ESC Bksp Exits and closes the dialog box or clears the character input as a back space key 8 Alphanumeric keys Includes a pos...

Страница 6: ...headphone 7 LAN interface option Connects to a PC for SCPI remote control 8 RF OUT connector The output for built in tracking generator enabled with Option TG7 9 Probe power Provides power for high i...

Страница 7: ...ation of the key light is settable to provide maximum battery life 1 1 Adjust the display brightness Instructions for HSA Keystrokes for HSA Switch the screen brightness state from automatic to manual...

Страница 8: ...interest 3 Adjust the amplitude to give the optimum view of the signal In this demonstration we will set signal generator to output a signal to N934xC HSA with an RF cable and set these parameters In...

Страница 9: ...ted BW Integrated BW 5 MHz Save file Shift Save input the file name WCDMA_CHP in the Save As dialog box and press Enter Turn on OBW Meas Meas Occupied BW Save file Shift Save input the file name WCDMA...

Страница 10: ...he top of the display after successful lock of GPS satellites Turn on GPS information on the display GPS Info On Location information from GPS displays on the right of icon Figure 3 Note The N934xC mu...

Страница 11: ...n 1 Save state file Instructions for HSA Keystrokes for HSA Set center frequency and span Freq Center Freq 2 GHz Span 10 MHz Task 1 Channel power Enter channel power Meas Channel Power Set integrated...

Страница 12: ...e on the PC screen Establish the connection between the PC and the N934xC HSA Click the connection shortcut in the toolbar as shown in Figure 5 Select the N934xC HSA in the connect instrument dialog b...

Страница 13: ...upper and lower limits can be set up to indicate the PASS FAIL of the measurement result 3 Save trace If this is selected the N934xC HSA will save the trace TRC at the end of the current task 4 Save...

Страница 14: ...choices see Figure 11 1 Auto Tasks are executed non stop until tasks are completed 2 Manual After one measurement task is finished there is a measurement result report and you can choose to Redo Redo...

Страница 15: ...le from the PC to N934xC HSA s Internal disc C Close the Data Transfer box N934xC HSA back to local mode Click the shortcut key of disconnection as shown in Figure 14 Press Enter on the N934xC HSA and...

Страница 16: ...r Esc to Confirm message appears Run task 2 OBW Press Enter after the obw begin Enter Esc to Confirm message appears Press Enter after the obw end Enter Esc to Confirm message appears Run task 3 ACPR...

Страница 17: ...e update interval time Turn on Marker 1 and Marker 2 Note Marker 1 is on by default MARKER Marker 2 State On Move marker to the location by setting frequency or time Frequency or Time rotating knob or...

Страница 18: ...earch each N934xC HSA also has a peak table feature which automatically searches 10 max or min peak signals simultane ously and is updated after each sweep In this demonstration we will use peak table...

Страница 19: ...n measurement using an external AM FM antenna Demonstration 9 Advance marker functions Instructions for HSA Keystrokes for HSA Connect an AM FM antenna such as 88 MHz to 108 MHz to HSA RF input port S...

Страница 20: ...de 10 dBm CW signal Preset FREQ 2 GHz AMPTD 10 dBm RF On Instructions for HSA Keystrokes for HSA Preset set center frequency and span Preset Freq 2 GHz Span 10 MHz Enter into limit menu Shift Limit Se...

Страница 21: ...ystrokes for the source Set 2 GHz center frequency amplitude 10 dBm W CDMA signal Preset Freq 2 GHz Amplitude 10 dBm Mode W CDMA Arb W CDMA 3GPP 12 2004 W CDMA On Mod On RF On Instructions for HSA Key...

Страница 22: ...SA Amptd 6 dBm Adjust the knob so that the marker on the analyzer reads 6 dBm Instructions for HSA Keystrokes for HSA Set the center frequency Freq Center Freq 1 GHz Set zero span Span Zero Span Set r...

Страница 23: ...urn on the tracking generator and set its output amplitude to 10 dBm Mode Track Generator Amplitude On 10 dBm Set start frequency and stop frequency Note Select frequencies appropriate for the device...

Страница 24: ...ut power of an external signal generator Demonstration 14 Power meter Instructions for the source Keystrokes for the source Set 2 GHz center frequency amplitude 10 dBm W CDMA signal Preset Freq 2 GHz...

Страница 25: ...nd contactus BP 9 7 17 DEKRA Certified ISO9001 Quality Management System www keysight com go quality Keysight Technologies Inc DEKRA Certified ISO 9001 2015 Quality Management System Evolving Since 19...