Diagrams 71
Table 6-3. Test Points (continued)
TEST POINT No. & Loc.
Signal Tested
Measurement and Conditions
A4 AC Input Board
Connect meter between TP 9 and 10, or 9 and 11, or 10 and 11, and measure approximately 220VAC or 440VAC.
J418-1/J417-7
AC Mains Voltage
J418-2/J417-8
AC Mains Voltage
J418-3/J417-9
AC Mains Voltage
K402 coil
24VDC Coil Voltage
Turns on PS, and after power-on initialization
test, reads approximately 24VDC.
A5 DC Rail Board
J430-1 (+) to J430-2 (-)
Rail #1 Voltage
Measure approximately 290VDC
J431-1 (+) to J431-2 (-)
Rail #2 Voltage
Measure approximately 290VDC
A6 Bias Board
J801-4 to J801-5
GPIB 5V Bias
+15
0.9V measure approx. 11VAC
J801-1 (+) to J801-2 (-)
Fan voltage
Measure 24Vdc
J827-1 (+) to J827-2 (-)
Inrush relay coil
Measure 24Vdc
J827-1 (+) to J827-3 (-)
Rail relay coil
Measure 24Vdc after power-on initialization test.
J816-3 to J816-4
24V Primary
Measure approximately 34VAC
R813
-15V bias
-15V
R806
+ 5V bias
+5V
R812
+15V bias
+15V
A3 FET Board
NOTE:
Because test points on the FET board are not accessible when the board is installed; troubleshooting must be
performed with the board removed from the power supply (refer to the disassembly procedures at the back of chapter 3).
1.
Turn off the power supply and remove the A3 FET Board with its heat sink assembly.
2.
Short the collectors of Q251 and Q253 or Q351 and Q353 by connecting the collector (case) of each transistor to
common ( E507) .
3.
Connect waveform generator to J200-1 and J200-2.
4.
Set generator to produce a 20 kHz, 20V p-p triangular waveform
5.
Connect 15V from an external supply to E206 or E306 (positive) and E207 or E307 (common).
E207/E307
Secondary common (Sheet 1,2)
Connect meter or scope common here. Make
measurements at test points 27 through 35.
U203-1/U303-1
Bias voltage (Sheet 1, 2)
+5V
U204-1/U304-1
Bias trip point (Sheet 1, 2)
Voltage goes from low (0V) to high (5V) at an
input of
12V; and from high to low at
13V.
U201-1/U301-1
Drive 1 waveform (Sheet 1)
See Figure 6-1
U201-12/U301-12
Drive 2 waveform (Sheet 2)
See Figure 6-1
U201-10/U301-10
Drive pulses (Sheet 1, 2)
See Figure 6-1
U201-7/U301-7
Drive pulses (Sheet 1, 2)
See Figure 6-1
U202-1/U302-1
Drive pulses (Sheet 1, 2)
See Figure 6-1
U202-7/U302-7
Drive pulses (Sheet 1, 2)
See Figure 6-1
U205-2
VREF voltage (Sheet 1)
1.7V
Содержание 669 A Series
Страница 2: ...Service Manual Keysight Series 669xA GPIB DC Power Supplies ...
Страница 3: ......
Страница 27: ......
Страница 56: ...Troubleshooting 53 Figure 3 15 3 Inch Front Panel Frame Assembly ...
Страница 57: ...54 Troubleshooting Figure 3 16 Assembly A10 Exploded View ...
Страница 58: ...Troubleshooting 55 Figure 3 17 Assembly A10 Exploded View 6690A ...
Страница 59: ...56 Troubleshooting Figure 3 18 Assembly A10 Exploded View 6691A 6692A ...
Страница 60: ...Troubleshooting 57 Figure 3 19 Three Phase Line Choke Subchassis Wiring ...
Страница 61: ...58 Troubleshooting Figure 3 20 24 Volt Fan Transformer ...
Страница 77: ...74 Diagrams Figure 6 1 Test Point Waveforms for Table 6 3 sheet 2 of 2 ...
Страница 79: ...Figure 6 3 A1 Front Panel Board Assembly Diagram ...
Страница 81: ...Figure 6 5 A2 GPIB Board Component Location ...
Страница 83: ...Figure 6 7 A3 FET Board Component and Test Point Location ...
Страница 87: ...Figure 6 11 A4 AC Input Board Component and Test Point Location 12 9 10 11 ...
Страница 89: ...Figure 6 13 A5 DC Rail Board Component and Test Point Location 13 14 ...
Страница 91: ...Figure 6 15 A6 Bias Board Component and Test Point Location 15 16 17 18 19 19 20 22 ...
Страница 94: ...Figure 6 17 Power Mesh Schematic Diagram All Models ...
Страница 103: ......