Keysight U3042AM20 User’s and Service Guide
45
U3042AM20
Controlling the Test Set with the Analyzer
SCPI Control Mode
The Command Processor feature allows you to send remote commands and
data to the analyzer’s rear-panel GPIB connector and Test Set I/O connector.
More information regarding the Command Processor can be found in the
Help menu.
Overview of the SCPI Control
The Command Processor allows you to send address and data to control an
external test set without creating a remote program. This allows you to
control the test set without Option 551, or in non-standard measurement
classes, such as Scalar Mixer/Converter, Swept IMD, Noise Figure Cold Source, etc.
The user is required to manually input address and data using the Command
Processor Console in the Help menu.
— Command Processor settings can not be saved or recalled.
— Address and data can be written from the Command Processor.
How to Access Command Processor
1. To access the Command Processor select
Utility > System > Configure > SICL/GPIB/SCPI -OR-
(System Setup > Remote Interface > SCPI Monitor Input > Show SCPI Parser
Console)
.
2. Check the SCPI Command Console box -OR-
(Show SCPI Parser Console)
box.
Figure 35
Command Console for 'A' Model Analyzers