Quick Start Guide
SCPI Command List
20
:AM:DEPTh <val>
:AM:DEPTh?
Set AM depth
:AM:SOURce INT|EXT|INT+EXT
:AM:SOURce?
Set AM source
:AM:RATE <val> <unit>
:AM:RATE?
Set AM rate
:AM:EXTCoupling AC|DC
:AM:EXTCoupling?
Set external coupling
FM
SCPI command
:FM:STATe ON|OFF|1|0
:FM:STATe?
Turn on/off FM
:FM:DEViation <val> <unit>
:FM:DEViation?
Set FM deviation
:FM:SOURce INT|EXT|INT+EXT
:FM:SOURce?
Set FM source
:FM:RATE <val> <unit>
:FM:RATE?
Set FM rate
:FM:EXTCoupling AC|DC
:FM:EXTCoupling?
Set external coupling
F
M
SCPI command
:PM:STATe ON|OFF|1|0
:PM:STATe?
Turn on/off
F
M
:PM:DEViation <val> <unit>
:PM:DEViation?
Set
F
M deviation
:PM:RATE <val> <unit>
:PM:RATE?
Set
F
M rate
Pulse SCPI
command
:PULM:STATe ON|OFF|1|0
:PULM:STATe?
Turn on/off pulse
:PULM:SOURce INT|EXT
:PULM:SOURce?
Set pulse source
:PULM:PERiod <val> <unit>
:PULM:PERiod?
Set pulse period
SCPI Command
Utility