background image

Notices

© Keysight Technologies, Inc. 
200

6

-201

4

No part of this manual may be 
reproduced in any form or by any 
means (including electronic storage 
and retrieval or translation into a 
foreign language) without prior 
agreement and written consent from 
Keysight Technologies, Inc. as 
governed by United States and 
international copyright laws.

Trademark Acknowledgments

Manual Part Number

N93

10

-9000

3

Edition

Edition 

3

June

 201

4

 

Printed in 

China

Published by:
Keysight Technologies

No 116 Tianfu 4th street

 

Chengdu

610041, China

Warranty

THE MATERIAL CONTAINED IN THIS 
DOCUMENT IS PROVIDED “AS IS,” 
AND IS SUBJECT TO BEING 
CHANGED, WITHOUT NOTICE, IN 
FUTURE EDITIONS. FURTHER, TO 
THE MAXIMUM EXTENT PERMITTED 
BY APPLICABLE LAW, KEYSIGHT 
DISCLAIMS ALL WARRANTIES, 
EITHER EXPRESS OR IMPLIED WITH 
REGARD TO THIS MANUAL AND 
ANY INFORMATION CONTAINED 
HEREIN, INCLUDING BUT NOT 
LIMITED TO THE IMPLIED 
WARRANTIES OF 
MERCHANTABILITY AND FITNESS 
FOR A PARTICULAR PURPOSE. 
KEYSIGHT SHALL NOT BE LIABLE 
FOR ERRORS OR FOR INCIDENTAL 
OR CONSEQUENTIAL DAMAGES IN 
CONNECTION WITH THE 
FURNISHING, USE, OR 
PERFORMANCE OF THIS 
DOCUMENT OR ANY INFORMATION 
CONTAINED HEREIN. SHOULD 
KEYSIGHT AND THE USER HAVE A 
SEPARATE WRITTEN AGREEMENT 
WITH WARRANTY TERMS 

COVERING THE MATERIAL IN THIS 
DOCUMENT THAT CONFLICT WITH 
THESE TERMS, THE WARRANTY 
TERMS IN THE SEPARATE 
AGREEMENT WILL CONTROL.

Technology Licenses

The hardware and/or software 
described in this document are 
furnished under a license and may be 
used or copied only in accordance 
with the terms of such license.

U.S. Government Rights

The Software is “commercial 
computer software,” as defined 
by Federal Acquisition Regulation 
(“FAR”) 2.101. Pursuant to FAR 
12.212 and 27.405-3 and 
Department of Defense FAR 
Supplement (“DFARS”) 227.7202, 
the U.S. government acquires 
commercial computer software 
under the same terms by which 
the software is customarily 
provided to the public. 
Accordingly, Keysight provides 
the Software to U.S. government 
customers under its standard 
commercial license, which is 
embodied in its End User License 
Agreement (EULA), a copy of 
which can be found at 

http://www.keysight.com/find/sweula

The license set forth in the EULA 
represents the exclusive authority 
by which the U.S. government 
may use, modify, distribute, or 
disclose the Software. The EULA 
and the license set forth therein, 
does not require or permit, 
among other things, that 
Keysight: (1) Furnish technical 
information related to 
commercial computer software 
or commercial computer 
software documentation that is 
not customarily provided to the 
public; or (2) Relinquish to, or 
otherwise provide, the  
government rights in excess of 
these rights customarily provided 
to the public to use, modify, 
reproduce, release, perform, 
display, or disclose commercial 
computer software or 
commercial computer software 

documentation. No additional 
government requirements 
beyond those set forth in the 
EULA shall apply, except to the 
extent that those terms, rights, or 
licenses are explicitly required 
from all providers of commercial 
computer software pursuant to 
the FAR and the DFARS and are 
set forth specifically in writing 
elsewhere in the EULA. Keysight 
shall be under no obligation to 
update, revise or otherwise 
modify the Software.  With 
respect to any technical data as 
defined by FAR 2.101, pursuant 
to FAR 12.211 and 27.404.2 and 
DFARS 227.7102, the U.S. 
government acquires no greater 
than Limited Rights as defined in 
FAR 27.401 or DFAR 227.7103-5 
(c), as applicable in any technical 
data.

Safety Notices

CAUTION

 notice denotes a hazard. It 

calls attention to an operating 
procedure, practice, or the like that, 
if not correctly performed or adhered 
to, could result in damage to the 
product or loss of important data. Do 
not proceed beyond a CAUTION 
notice until the indicated conditions 
are fully understood and met. 

WARNING

 notice denotes a hazard. 

It calls attention to an operating 
procedure, practice, or the like that, 
if not correctly performed or adhered 
to, could result in personal injury or 
death. Do not proceed beyond a 
WARNING notice until the indicated 
conditions are fully understood and 
met.

Содержание N9310A

Страница 1: ...gnal Generator Notice This document contains references to Agilent Please note that Agilent s Test and Measurement business has become Keysight Technologies For more information go to www keysight com...

Страница 2: ...overnment customers under its standard commercial license which is embodied in its End User License Agreement EULA a copy of which can be found at http www keysight com find sweula The license set for...

Страница 3: ...enerating a Modulated Signal 13 Some Help Hints 15 Remote Control 16 Contact Keysight Technologies 22 Factory Default Settings 23 This Quick Start Guide helps you in preparing the signal generator for...

Страница 4: ...signal generator includes the following items as standard Verify if the ordered options are included in the shipment by checking the serial number on the rear panel of the signal generator Any questi...

Страница 5: ...ectrical shock may result if the signal generator is connected from the power supply while cleaning Do not attempt to clean internally CAUTION To install the signal generators in other racks note that...

Страница 6: ...signal Low frequency LF signal RF LF Amplitude step sweep Amplitude modulation AM signal Frequency modulation FM signal Phase modulation FM signal Pulse modulation signal The signal generator comprise...

Страница 7: ...AM FM Pulse Utility Sweep Trigger Local File LF Out 1 8 9 10 11 12 13 18 17 16 15 14 7 5 6 4 3 2 REVERSE PWR 4W MAX 30VDC 1 Screen 10 RF On Off hardkey 2 Softkeys 11 RF OUT connector 3 Enter key 12 L...

Страница 8: ...PULSE MOD IN REF IN REF OUT I IN 1V RMS MAX Q IN LINE 100 240V 50 60Hz 100W MAX Made in China HIPOT PASS N9310A N9310A CFG002 SER CN 1 3 4 6 7 8 9 10 11 12 2 5 1 AC power switch 7 Pulse input connect...

Страница 9: ...er socket provided with a protective earth Set the tilt adjustor for your preference Figure 1 Plug in and angle adjustment 2 Connect an RF cable to the output connector of the signal generator and the...

Страница 10: ...LED will light Self initialization takes about 30 seconds the signal generator then defaults to the menu mode with the maximum frequency of 3 GHz and minimum amplitude of 127 dBm then the signal gener...

Страница 11: ...dkey Frequency becomes the active function in the data entry area This area displays the factory preset frequency 3 Enter 1 using the numeric keypad and press GHz softkey The FREQUENCY area and the ac...

Страница 12: ...ing a Continuous Wave Signal 10 Enable RF Output Figure 3 CW output Screenshot Operation Notes Press hardkey Notice that the display annunciator changes from to The CW signal is now available at the R...

Страница 13: ...ess hardkey Sets the signal generator to its factory defined instrument state 2 Press hardkey Enables the submenu of sweep softkeys 3 Press Step Sweep softkey Enables the submenu of sweep settings 4 P...

Страница 14: ...RF OUT connector Notice that the display annunciator changes from to 2 Press Return Sweep Mode Displays another menu allowing you to choose the sweep mode 3 Press RF softkey The indicates sweep on sig...

Страница 15: ...tion Operation Notes 1 Press hardkey Sets the signal generator to its factory defined instrument state 2 Press 900 MHz Sets the carrier frequency to 900 MHz for amplitude modulation 3 Press 20 dBm Set...

Страница 16: ...ore information Operation Notes Press hardkey The display annunciator changes from to The AM signal is now available at RF OUT connector RF On Off NOTE After pressing hardkey will display on the scree...

Страница 17: ...either local memory or an external USB memory by pressing Save Connect and set an external reference by pressing Ref Setups Connect an external display monitor to the VGA connector for the education p...

Страница 18: ...MHz processor 128 MB RAM 175 MB available disk space Microsoft Windows XP or Windows 7 Display resolution 800 600 Frequency Enter 7 MOD On Off RF 4 1 0 2 9 6 3 On Off Amplitude FM Utility LF Out Pres...

Страница 19: ...p www keysight com find iolib Follow the windows wizard to finish the installation Then you have successfully set up an environment for remotely control your N9310A Connecting your N9310A to a Control...

Страница 20: ...STOP Set LF stop frequency FREQuency RF SCALe LOG LIN FREQuency RF SCALe Set Sweep Scaling Amplitude SCPI command AMPLitude CW val unit AMPLitude CW Set CW frequency AMPLitude STARt val unit AMPLitud...

Страница 21: ...e STOP Set stop amplitude SWEep STEP POINts val SWEep STEP POINts Set sweep point SWEep STEP DWELl val unit SWEep STEP DWELl Set step dwell time SWEep REPeat SINGle CONTinuous SWEep REPeat Set sweep r...

Страница 22: ...iation Set FM deviation FM SOURce INT EXT INT EXT FM SOURce Set FM source FM RATE val unit FM RATE Set FM rate FM EXTCoupling AC DC FM EXTCoupling Set external coupling FM SCPI command PM STATe ON OFF...

Страница 23: ...Play WHITE BLUE GREEN SYSTem DISPlay Set display style SYSTem SSAVer ON OFF 1 0 SYSTem SSAVer Set screen saver SYSTem ERRor View error messages SYSTem DATE year month day SYSTem DATE Set system date S...

Страница 24: ...rator by its product number and full serial number Press Information to find those information Online assistance http www keysight com find assist United States tel 800 829 4444 fax 800 829 4433 Canad...

Страница 25: ...500 mV Modulation Mod On Off On Modulation State Off RF On Off Off AM Depth 0 0 Sweep FM Deviation 0 000 rad Sweep Mode Off FM Deviation 20 Hz RF Start 9 0000 kHz Pulse Period 200 s RF Stop 3 000 000...

Страница 26: ...This information is subject to change without notice Keysight Technologies 2006 2014 Edition 3 June 2014 www keysight com N9310 90003...

Отзывы: