Step 7: Install User Application Modules in the AXIe Chassis

AXIe chassis are shipped with filler panel modules on all except Slot 1. You may 

need to remove filler panels from covered slots.

Install Application Module Drivers (if necessary)

Each installed application module typically requires device drivers and control 

software. You need not install them to verify basic chassis operation. However, 

you would need to install them on the M9537A controller if required by your user 

application module. Consult the module provider for software requirements and 

instructions.

Chassis Shutdown

As with any PC, you should not shut down Windows-based instruments by either 

turning off the power via an external power source or by pulling the power plug 

out from the rear panel. This could corrupt the operating system. The only 

approved way to shut down the controller is to execute the Windows shutdown 

process and then turn off the chassis via the chassis On/Off button.

Certain modules require bus master and/or Rear I/O capability. If 

you are in doubt whether such features are required for the 

module you intend to install, check your specific module and/or 

system documentation to make sure that your system is provided 

with an appropriate free slot in which to insert the board.

You may need to connect the embedded controller to the internet. 

Locate and install the necessary drivers from the internet.

Pressing the chassis power button immediately removes power 

from the controller. This may cause loss of data or damage to the 

controller.

Содержание M9537A

Страница 1: ...Keysight M9537A AXIe Embedded Controller Startup Guide...

Страница 2: ......

Страница 3: ...anty THE MATERIAL CONTAINED IN THIS DOCUMENT IS PROVIDED AS IS AND IS SUBJECT TO BEING CHANGED WITHOUT NOTICE IN FUTURE EDI TIONS FURTHER TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW KEYSIGHT DIS...

Страница 4: ...erform proce dures involving cover or shield removal unless you are qualified to do so DO NOT operate damaged equipment Whenever it is possible that the safety protection features built into this prod...

Страница 5: ......

Страница 6: ...vi...

Страница 7: ...down modes 10 Using the LAN ports 12 LAN port recommendations 13 Embedded system module LAN connection 14 Step 4 Windows Configuration Review 15 Microsoft Windows OS is Activated 15 Windows Security 1...

Страница 8: ...viii Keysight M9537A AXIe Embedded Controller Startup Guide...

Страница 9: ......

Страница 10: ......

Страница 11: ...keysight com find M9502A or www keysight com find M9505A The drivers and Keysight s IO Libraries Suite installed on the M9537A controller are the current versions available when the module shipped fr...

Страница 12: ...uate ESD protection when used alone To ensure user safety the static safe accessories must provide at least 1 M of isolation from ground Both methods when used together provide a significant level of...

Страница 13: ...ldwide contact information for repair and service or refer to the support information on the product web page at www keysight com find M9537A 3 Write the following information on a tag and attach it t...

Страница 14: ...and carton If the original carton is not available use bubble wrap or packing peanuts Place the instrument in a sealed container and mark the container FRAGILE 5 On the shipping label write ATTENTION...

Страница 15: ...eyboard mouse video monitor are not included with the M9537A The operating system has been installed for you at the factory You do not require any other drivers to operate the controller module Howeve...

Страница 16: ...r injector handles 4 Carefully align the M9537A board edges with the chassis guide rails and insert the controller into the chassis guide rails 5 Check that the catch hooks and alignment pins at both...

Страница 17: ......

Страница 18: ...down procedure is to execute the Windows shutdown process and then turn off the chassis via the chassis On Off button Windows OS Versions The M9537A AXIe Embedded Controller ships with either Windows...

Страница 19: ...ut down button To restart the controller click Windows Start click the power ICON then click Restart Do not enable the Microsoft Windows sleep mode It is possible that the M9537A controller could go i...

Страница 20: ...of three LAN ports accessible on the front panels Two LAN ports are on the M9537A controller and one on the Embedded System Module ESM Windows Device Manager shows four individual Network Interface C...

Страница 21: ...le if you connect the LAN cable to the ESM when power is first applied to the chassis and subsequently you move the cable to one of the two LAN ports on the controller while the chassis is still power...

Страница 22: ...ESM Therefore whenever you change the ESM LAN connection do the following 1 Power down the M9537A using the Shut down selection on the Windows Start menu 2 After shut down is complete power down the c...

Страница 23: ...ick System 3 Scroll down to the bottom of the screen Under Windows Activation you can view the activation status Windows Security If your system is connected to the Internet you should take the follow...

Страница 24: ...em performance and some Windows Updates automatically reboot the controller Therefore Windows updates should be performed when the system is not in normal use There is no 3rd party anti virus software...

Страница 25: ...een 2 Click Settings from the list to the left 3 Select Accounts 4 Select Sign in options from the menu 5 Click on Change under Change your account password How to set or change your password for Wind...

Страница 26: ...ms and data files You should regularly create a system image so that all data applications etc have backups The system image may be stored on a USB memory stick multiple CD DVDs an external USB hard d...

Страница 27: ...Ie Embedded Controller Startup Guide 19 Step 4 Windows Configuration Review Some third party backup utilities may destroy Keysight s Recovery System partition If this happens the Keysight Recovery Sys...

Страница 28: ...e Task bar click the Keysight Connection Expert icon Locate your AXIe in the Keysight Connection Expert Chassis tab as shown in the following picture The Keysight IO Libraries is pre installed on the...

Страница 29: ...g correctly follow these simple steps 1 Boot up the M9537A and verify basic Windows operation by using the monitor keyboard and mouse 2 Verify that you have network access by opening the browser to a...

Страница 30: ...tic electricity To minimize electrostatic damage take the necessary anti static precautions Both chassis provide a grounding terminal to which you can connect a wrist strap Empty Slots Except for perf...

Страница 31: ...ed instruments by either turning off the power via an external power source or by pulling the power plug out from the rear panel This could corrupt the operating system The only approved way to shut d...

Страница 32: ...find out which version is currently installed in your M9537A you can either boot to the BIOS screen or you can run the msinfo32 exe reporting tool from within WES 7 To look up the BIOS version via th...

Страница 33: ...midity are controlled Condensation can pose a potential shock hazard Condensation can occur when you move the module from a cold to a warm environment or if the temperature and or humidity of the envi...

Страница 34: ...ter Y1262A Display Port Cable Y1266A Spare SSD with Carrier WES 764 bit OS installed 240 GB This is not compatible with the Keysight M9036A or M9037A PXIe Embedded Controller Y1266B Spare SSD with Car...

Страница 35: ......

Страница 36: ...This information is subject to change without notice Keysight Technologies Inc 2018 Published in USA Edition 5 March 2018 M9537 90001 M9537 90001 www keysight com...

Отзывы: