background image

04 | Keysight | M9393A PXIe Performance Vector Signal Analyzer 9 kHz to 8.4 GHz, 14 GHz, 18 GHz or 27 GHz - Configuration Guide

Step 1. If selecting an embedded controller, select either M9036A or M9037A

1

M9036A-M04
Mid-performance embedded controller
Intel i5-520E dual-core, 2.4 GHz, 4 thread, 4GB RAM

Select the M9036A for mid-performance, lower cost or if your  
application requires XP operating system

M9037A-M04 
High-performance embedded controller
Intel i7-4700EQ quad-core processor, 2.4 GHz, 8 thread, 4GB RAM

Select M9037A for the best performance if you have memory  
intensive applications, multiple applications running in parallel, or 
if a lot of data is sent to the PC from the PXIe chassis.  Features 
removable SSD drive for security and x8 connector from front for 
connection to second chassis

Step 2. Upgrade from standard memory size (optional)

For M9036A

M9036A-M08

Memory upgrade from 4 GB to 8 GB RAM

For M9037A

M9037A-M08

Memory upgrade from  4 GB to 8 GB RAM

M9037A-M16

Memory upgrade from  4 GB to 16 GB RAM

Step 3. Select an operating system

For M9036A

M9036A-WE3    

Microsoft Windows Embedded Standard 7 (32-bit)

M9036A-WE6    

Microsoft Windows Embedded Standard 7 (64-bit)

For M9037A

M9037A-WE3

Microsoft Windows Embedded Standard 7 (32-bit)

M9037A-WE6

Microsoft Windows Embedded Standard 7 (64-bit)

C. Select controller (either embedded controller or via PC)

1. 

The M9018A 18-slot chassis includes empty space to the left of the 1

st

 functional slot. The embedded controller occupies that empty space and the 1

st

 

functional slot.

Содержание M9393A

Страница 1: ...Keysight M9393A PXIe Performance Vector Signal Analyzer 9 kHz to 8 4 GHz 14 GHz 18 GHz or 27 GHz Configuration Guide...

Страница 2: ...ect services Warranty calibration start up assistance 10 Multiple M9393A PXIe performance VSAs in a single chassis 10 Configuration Single M9393A PXIe performance VSA 11 Single PXIe performance VSA M9...

Страница 3: ...s bandwidth M9393A B04 40 MHz Included in base configuration M9393A B10 100 MHz M9393A B16 160 MHz Step 4 Choose memory size M9393A M01 128 MSa Included in base configuration M9393A M05 512 MSa M9393A...

Страница 4: ...the PC from the PXIe chassis Features removable SSD drive for security and x8 connector from front for connection to second chassis Step 2 Upgrade from standard memory size optional For M9036A M9036A...

Страница 5: ...pressCard adaptor Y1200B PCIe cable M9021A PCIe cable interface1 1 slot To use your Desktop PC as a controller M9048A PCIe desktop adaptor Y1202A PCIe cable M9021A PCIe cable interface1 1 slot C Selec...

Страница 6: ...212A Slot blocker kit 5 slots Y1213A PXI EMC filler panel kit 5 slots Step 3 Choose a rack mount kit optional Y1215A Rack mount kit for M9018A 18 slot PXIe chassis Step 4 Choose an air inlet kit optio...

Страница 7: ...07 Keysight M9393A PXIe Performance Vector Signal Analyzer 9 kHz to 8 4 GHz 14 GHz 18 GHz or 27 GHz Configuration Guide Physical Connections Physical connection diagram for controllers...

Страница 8: ...ate code for command sequences in MATLAB Visual C Visual Basic NET and Visual C C Profile command execution time Debug command sequences using breakpoints and single stepping Step 3 Add X Series Measu...

Страница 9: ...ypes of presets 89601B BHF Custom OFDM modulation analysis of propriety and pre standard OFDM formats 89601B B7R WLAN 802 11a b g j p 89601B B7Z WLAN 802 11n MIMO 89601B BHJ WLAN 802 11ac MIMO require...

Страница 10: ...grades the global warranty to provide 5 day typical turnaround repair service in the US Japan China and many EU countries or up to a 10 day improvement in turnaround time in the rest of the world Prio...

Страница 11: ...e for detailed cabling diagram and parts list Additional cables shipped One 8121 2063 BNC Male SMB Female 1200mm for external reference connection One 8120 5091 SMB Female SMB Female 120mm for shorter...

Страница 12: ...our M9393As in a single M9018A chassis Multiple PXIe performance VSAs in a single PXIe chassis It is recommended that you install the M9393A modules entirely in consecutive slots beginning with slot 2...

Страница 13: ...ght chassis The M9393A with M9300A frequency reference can be successfully installed in a non Keysight PXI chassis Please use the following guidelines Ensure that the chassis has 5 consecutive PXIe or...

Страница 14: ...isted countries www keysight com find contactus BP 9 7 17 DEKRA Certified ISO9001 Quality Management System www keysight com go quality Keysight Technologies Inc DEKRA Certified ISO 9001 2015 Quality...

Отзывы: