Notices

© 2011-2012 Agilent Technologies, Inc.

No part of this manual may be reproduced in

any form or by any means (including

electronic storage and retrieval or

translation into a foreign language) without

prior agreement and written consent from

Agilent Technologies, Inc. as governed by

United States and international copyright

laws.

Manual Part Number

M9202-90001

Edition

21 November 2012

Sales and Technical Support

To contact Agilent for sales and technical

support, refer to the “support” links on the

following Agilent web resources:

n

http://www-

.agilent.com/find/embedded

n

www.agilent.com/find/assist

(worldwide contact information for

repair and service)

Information on preventing damage to your

Agilent equipment can be found at

www.agilent.com/find/tips

.

Regulatory Compliance

This product has been designed and tested

in accordance with accepted industry

standards, and has been supplied in a safe

condition. To review the Declaration of

Conformity, go to

http://regulations.corporate.agilent.com

/DoC/search.htm

.

Warranty

The material contained in this document is

provided “as is,” and is subject to being

changed, without notice, in future editions.

Further, to the maximum extent permitted by

applicable law, Agilent disclaims all

warranties, either express or implied, with

regard to this manual and any information

contained herein, including but not limited to

the implied warranties of merchantability

and fitness for a particular purpose. Agilent

shall not be liable for errors or for incidental

or consequential damages in connection with

the furnishing, use, or performance of this

document or of any information
contained herein. Should Agilent and the

user have a separate written agreement with

warranty terms covering the material in this

document that conflict with these terms, the

warranty terms in the separate agreement

shall control.

Technology Licenses

The hardware and/or software described in

this document are furnished under a license

and may be used or copied only in

accordance with the terms of such license.

Restricted Rights Legend

If software is for use in the performance of a

U.S. Government prime contract or

subcontract, Software is delivered and

licensed as “Commercial computer software”

as defined in DFAR 252.227-7014 (June

1995), or as a “commercial item” as defined

in FAR 2.101(a) or as “Restricted computer

software” as defined in FAR 52.227-19 (June

1987) or any equivalent agency regulation or

contract clause. Use, duplication or

disclosure of Software is subject to Agilent

Technologies’ standard commercial license

terms, and non-DOD Departments and

Agencies of the U.S. Government will receive

no greater than Restricted Rights as defined

in FAR 52.227-19(c)(1-2) (June 1987). U.S.

Government users will receive no greater

than Limited Rights as defined in FAR

52.227-14 (June 1987) or DFAR 252.227-

7015 (b)(2) (November 1995), as applicable

in any technical data.

Safety Notices

The following safety precautions should be

observed before using this product and any

associated instrumentation.

This product is intended for use by qualified

personnel who recognize shock hazards and

are familiar with the safety precautions

required to avoid possible injury. Read and

follow all installation, operation, and

maintenance information carefully before

using the product.

If this product is not used as specified, the

protection provided by the equipment could

be impaired. This product must be used in a

normal condition (in which all means for

protection are intact) only.

The types of product users are:

n

Responsible body

is the individual or

group responsible for the use and

maintenance of equipment, for ensur-

ing that the equipment is operated

within its specifications and oper-

ating limits, and for ensuring oper-

ators are adequately trained.

n

Operators

use the product for its

intended function. They must be

trained in electrical safety pro-

cedures and proper use of the instru-

ment. They must be protected from

electric shock and contact with haz-

ardous live circuits.

n

Maintenance personnel

perform rou-

tine procedures on the product to

keep it operating properly (for exam-

ple, setting the line voltage or replac-

ing consumable materials).

Maintenance procedures are

described in the user documentation.

The procedures explicitly state if the

operator may perform them. Other-

wise, they should be performed only

by service personnel.

n

Service personnel

are trained to

work on live circuits, perform safe

installations, and repair products.

Only properly trained service per-

sonnel may perform installation and

service procedures.

Agilent products are designed for use with

electrical signals that are rated

Measurement Category I and Measurement

Category II, as described in the International

Electrotechnical Commission (IEC) Standard

IEC 60664. Most measurement, control, and

data I/O signals are Measurement Category

I and must not be directly connected to

mains voltage or to voltage sources with

high transient over-voltages. Measurement

Category II connections require protection

for high transient over-voltages often

Содержание Agilent Technologies PXI Express M9202A

Страница 1: ...bit Wideband IF Digitizer M9202A Startup Guide NOTICE This document contains references to Agilent Technologies Agilent s former Test and Measurement business has become Keysight Technologies For more...

Страница 2: ...or contract clause Use duplication or disclosure of Software is subject to Agilent Technologies standard commercial license terms and non DOD Departments and Agencies of the U S Government will recei...

Страница 3: ...the voltage being measured The instrument and accessories must be used in accordance with its specifications and operating instructions or the safety of the equipment may be impaired Do not exceed th...

Страница 4: ...nt means caution risk of danger You should refer to the operating instructions located in the user documen tation in all cases where the symbol is marked on the instrument This symbol indicates the ti...

Страница 5: ...anel Connectors 13 Front Panel LED 13 Step 5 Verify Operation of the M9202A Module 14 Conducting a Self Test 15 Conduct M9202A Operational check optional 16 Requirements for Verification 16 Required H...

Страница 6: ...Documentation Map 6 M9202A PXI Express 12 bit Wideband IF Digitizer Startup Guide...

Страница 7: ...elect Technical Support Manuals l Help system for the Soft Front Panel l Help systems for the device drivers IVI C and IVI COM and LabVIEW G l Specifications Data Sheet Follow the Startup Sequence Thi...

Страница 8: ...spect for damage After unpacking the module carefully inspect it for any shipping damage Report any damage to the shipping agent immediately as such damage is not covered by the warranty Warranty info...

Страница 9: ...instrument or prevent it from moving in the shipping container Styrene pellets can also cause equipment damage by generating static electricity or by lodging in fan motors If any correspondence is req...

Страница 10: ...r operation than is required for installation The amount of space listed above is required for installation 2 Note NET Framework Runtime Components are installed by default with Windows Vista Therefor...

Страница 11: ...llowing l Agilent IO Library Suite IOLS which includes the Agilent Connection Expert This software must be installed first Version 16 2 or newer of the Agilent IO Libraries Suite is required l Soft Fr...

Страница 12: ...e triangle symbol 5 Install the module into the appropriate slot of the chassis by placing the module card edges into the front mod ule guides top and bottom Ensure that the ejector handle is pushed d...

Страница 13: ...t This input is AC cou pled and 50 terminated The recommended signal level is 1 V pk pk 4 dBm The clock signal frequency should be half of the desired sampling frequency TRG OUT This MMCX female conne...

Страница 14: ...202 module is recognized 3 Select the M9202A module and check that the correct Model Name appears in the Instrument Properties 4 Select the Installed Software tab and review the configuration data as...

Страница 15: ...e with the processor controlling it When the SFP is launched it will initiate a self calibration which takes a little over 1 minute Verify that no error is shown in the lower left hand log area The im...

Страница 16: ...or 1x BNC MMCX cable 50 Coaxial 100 cm Operational Verification Procedure Do not exceed the maximum power level to the INPUT connector 0 5 W 1 Launch the soft front panel SFP The calibration must succ...

Страница 17: ...cilloscope 3 If the problem occurs during Operational Verification disconnect the input signal and note the status of the LED on the front panel it should be GREEN Reconnect the signal and select the...

Страница 18: ...ers Manufacturers Group PCIe and PCI EXPRESS are registered trademarks and or service marks of PC SIG Microsoft Windows VisualStudio VisualC VisualC and VisualBasic are either registered trademark or...

Отзывы: