KL/RX2
Master Control Panel
PLEASE ENSURE THE FOLLOWING PRECAUTIONS ARE TAKEN WHEN USING ANY OF THE PRODUCTS:
1. Disconnect the main electrical supply before carrying-out any work.
2. Ensure no forces act on the switch terminals after installation.
3. NB. There is a danger to life and risk of injury with electrically operated windows!
The window motor stops by an electronic ‘limit stop’ or ‘overload cut-off’. The resulting forces are strong
enough to crush body parts. Please attach the safety sticker to be clearly visible on the frame of the roof
window. Please ensure that occupants are aware that the window can be closed automatically or by a
remote switch.
4. We recommend only a suitably qualified electrician should install and connect all electrical devices.
INSTALLATION PROCEDURES:
KL/RX2-2012G
THE INSTALLATION OF THIS SYSTEM MUST BE CARRIED OUT BY A QUALIFIED ELECTRICIAN
THE GUARANTEE WILL BE VOIDED IF THIS IS NOT FOLLOWED
MOTOR INSTALLATION
If the interior ceiling is not finished, the cable can
be passed through the pre-drilled hole by removing
the thimble (fig 1a).
1a
Please note:
All Installation Procedures are viewed from inside the room.
1b
If the ceiling is finished a 10mm hole must be
drilled through the top of the frame (figs 1b, 1c &
1d), 20mm down from top and 145mm in from
the side of the frame.
1c
1d
20mm
145mm
2a
2b
Feed the cable up through the hole (fig. 2a or 2b).