iButton Series Programming Guide
Section: Programming Guide Non-Software
Lock Schedule Programming Examples
•
How to program a basic automatic command for 'passage mode' on a weekly schedule
Example: A business wants to schedule the lock to enter passage mode Monday through
Friday at 8:30am and return to 'Storehouse mode' at 5:30pm. After 8:30am a valid user can
unlock the lock. It will then stay unlocked until 5:30pm unless a valid user re-locks the door. At
5:30pm the lock will automatically re-lock by itself. After 5:30, valid users can still open the
lock, however the lock will automatically re-lock itself 5 seconds later to prevent the door from
accidentally being left unlocked. (remember, 24 hr time)
Enter: #23456#15#12345#08301730#
#23456#
15#
12345#
0830
1730#
Master Code
Function code
Mon-Fri
Start time
End Time
If the desire is for the lock to be in 'Passage mode' at all times, ' Passage mode' times should
be from 12:01am (0001) to 11:59pm(2359). This is because the lock
MUST
be in 'Storehouse
mode' when the date changes at midnight each night, if only very briefly. Since the default lock
mode is 'Storehouse mode', the 2 minute gap in the times for 'Passage mode' around midnight
allows this to occur.
•
Practical program to automatically unlock / lock on days at particular times
Example: A business wants to have the lock automatically unlock at 8:00am and re-lock at
5:00pm Monday-Friday on a connecting door, without any user intervention. (remember, 24 hr
time)
Enter: #23456#63#0800#
automatically unlocks door at 8:00 am
Enter: #23456#64#
enables auto-unlock feature
Enter: #23456#67#
enables auto-lock function
Enter: #23456#15#12345#07591700#
set passage mode start at 7:59am, ending at 5:00pm
Note
: The reason for 'Passage mode' to start at 7:59am and 'Auto-unlock' to occur at 8:00am is
because the lock must already be in 'Passage mode' before the 'Auto-unlock occurs, otherwise
the lock would re-lock itself 5 seconds later.
The lock needs at least 1 minute between command times. It is not required to use an 'Auto-
lock' time command in this one case, as the lock will lock itself without an 'Auto-lock' command
any time it leaves 'Passage mode' and enters the default 'Storehouse mode'.
Keyless Enty Locks
For current prices, please visit our website.
www.KeylessEntyLocks.com
46 Danada Sq West #4133
Phone: (630) 909-9504
Wheaton, IL 60189
Page 19 of 58
FAX: (630) 447-3635
LockO
Path: Z:\KEY\suppliers\Lockey\website-KEL-zc\_dev\pdfs Modified 08/1
2
©KeylessEntryLocks.com
©KeylessEntryLocks.com
©KeylessEntryLocks.com
©KeylessEntryLocks.com
©KeylessEntryLocks.com
©KeylessEntryLocks.com
©KeylessEntryLocks.com
©KeylessEntryLocks.com
©KeylessEntryLocks.com
©KeylessEntryLocks.com
©KeylessEntryLocks.com
©KeylessEntryLocks.com
©KeylessEntryLocks.com
©KeylessEntryLocks.com
©KeylessEntryLocks.com
©KeylessEntryLocks.com