The reset button is located just below the battery holder in a recessed hole. Use a narrow object
such as a straightened paper clip to press the button in. Press and hold the reset button below the
battery holder. The LED in the center of the iButton reader will light green. After 5 seconds the
lock will beep once. Continue to hold the button down until the LED flashes red slowly. Release
the reset button immediately and press the # key while the LED is still flashing. The lock will beep
3 times, indicating the reset and clear has been successful.
Lock Manufacturer Default Settings, E4 / E5:
These settings apply for a new lock or one that has had a full reset as per the reset procedures above:
•
Default master code: 123456
•
Auto unlock/lock: Disabled
•
Default lock mode: Storehouse mode
•
Default Daylight savings mode: Disabled
•
Construction code: 0#, only applies until first regular user code is programmed.