background image

TRONIC

 MIFARE 

10 

www.keya.cat 

TABLE READER/WRITER 
 
Used to read/write information from/to cards and 
bracelets. 
In conjuntion with the software, the table reader is an 
essential accessory to achieve a complete management 
of RFID installations. 
The use of the table reader allows management 
functions from a remote place (i.e. reception desk) such 
as: 
- Create and delete management/master/user tags 
- Read relevant information from the tag (locker Nr., user 
ID, battery level) 
- Assign users to locks, limiting time of use 
(hours/days/months). 
- Read last events of the locks. 
- Read all settings from locks. 
- Create SETTINGS CARD to modify the parameters of 
the locks. 

TRONIC INFOTERMINAL 
 
The Infoterminal is as an autonomous information point 
for users. It is mainly used by clients to read their cards 
and bracelets and know their locker number. 

Содержание TRONIC MIFARE

Страница 1: ...TRONIC MIFARE...

Страница 2: ...TRONIC MIFARE 2 www keya cat...

Страница 3: ...TRONIC MIFARE MANAGEMENT CARD MASTER CARDS USER CARDS www keya cat 3...

Страница 4: ...er cards MASTER CARD Functions Create Delete User cards Single user only Inspection mode and Delete User cards USER CARD Functions Open Close locks SETTINGS CARD Functions Transfer parameters from sof...

Страница 5: ...ps Master card not created DELETE Approach the Management card followed by the Master card Red LED 3 fast blinks and 3 short beeps Master card deleted 1 Create and delete Master cards TRONIC MIFARE ww...

Страница 6: ...eated per lock Green LED and long beep User card created successfully Red LED and 3 short beeps User card not created DELETE Approach the Master card followed by the User card Red LED 3 fast blinks an...

Страница 7: ...er card 1 time Green LED and long beep Lock opens during 30 seconds After inspection time lock closes automatically User card is not deleted 5 DELETE USER CARD Approach the Master card 2 times Green L...

Страница 8: ...user mode Approach the Master card 4 times All User cards of this lock have now been deleted Delete User cards 7 Approach the Master card 5 times followed by the Used card to be delete 3 short beeps U...

Страница 9: ...options Leave door open Close door again ACOUSTIC SIGNAL VOLUME High Low Off LED INDICATION OF CLOSED POSITION On Off blinking red LED when locker is closed CODES User Master LAST EVENTS BATTERY LEVEL...

Страница 10: ...e place i e reception desk such as Create and delete management master user tags Read relevant information from the tag locker Nr user ID battery level Assign users to locks limiting time of use hours...

Страница 11: ...10 200 Hz 2g Life test 200000 cycles Electrostatic discharge 8000 V Battery life 35000 cycles Measurements Torx T20 4 x AA LR6 Batteries replacement IMPORTANT The batteries replacement must be done i...

Страница 12: ...ENG Rev3 775010...

Отзывы: