23
EN
6 - TROUBLESHOOTING
Error Code
Symptoms
Checks
E01
LVD
Manually recharge the battery.
E02
Excessive load current and load switched off
Reduce load current at load output, and switch on load manually or
wait for 10 mins for auto switch-on by controller.
E03
Short circuit at load output and load switched off
Rectify short circuit and switch on load manually or wait for 5 mins
for auto switch-on by controller.
E04
HVD
Make sure connection between battery and controller is good;
make sure battery capacity is not too low. When battery voltage is
0.5V lower than defined overvoltage protection point, load switched
on automatically by controller.
E05
Battery charging switched off due to
over-temperature of controller
Allow the controller to cool down and restart charging automatical-
ly.
E06
Over-voltage of solar panel
Make sure voltage of open circuit is not too high.
E07
Charging switched off by controller due to excessi-
ve solar panel current
Check power of solar panel and reduce solar panel quantity in
parallel connection and wait for 2 mins for restart charging.
Symptoms
Checks
No sign on LCD initialization
Make sure no reverse connected battery and connection between
battery and controller is good; make sure circuit of battery switched
on and fuse protector connected.
No charging current
Make sure no reverse connected solar panel and connection
between solar panel and controller is good with no open circuit.
Load not work
Make sure ther’s no reverse connected load and controller is not in
protection against overload, short circuit, under-voltage or overvol-
tage.
Load not switched on at preset point
Make sure load controlling mode is correctly set; make sure battery
voltage not too low.
Load unable to be switched on at night in Light control mode
Make sure load controlling mode is correctly set and check solar
panel not illuminated by other light sources at night.
6.1 - Error code and correction
6.2 - Symptoms and correction
Code
Working mode
L00
Load always active (DEFAULT)
L01
Sunlight control with switch off at sunset and switch on at sunrise (NIGHT 1)
L02
Sunlight control with switch switch off point after sunset (time adjustable) and switch on before sunrise (NIGHT 2)
Different load controlling modes define parameters adjustable and interface displayed.
*
*
* period adjustable separately.
L00
L01
L02