17
EN
Consumption chart
2.7 - Installation example
B
W
A
ITEM
STATUS
FUNCTION
A/h
W
CT10224
in stand-by no accesories
SBY=1
0,0350
0,83
CT20224
in stand-by no accesories
SBY=1
0,0270
0,65
MA24 with one PO24(gate closed)*
in stand-by no accesories
ENERGY SAVING=1
0,0195
0,47
in stand-by no accesories with RX4X/RX4Y
ENERGY SAVING=1
0,0235
0,56
MA24 with two PO24(gate closed)*
in stand-by no accesories
ENERGY SAVING=1
0,0210
0,51
in stand-by no accesories with RX4X/RX4Y
ENERGY SAVING=1
0,0250
0,6
FT32/22
One TX and one RX during activation
in function
0,0290
0,69
ECLIPSE
COURTESY light on
in function
0,0325
0,77
FLASHLIGHT on
in function
0,0200
0,99
LED strip (18 leds)
in function
0,0325
0,77
* For MA24 no DYL (display) connected
Example of installation with SUN11024 and with 12 hours
Night Light System (NLS) (E cover LED strip) and
without Night Light System.
ATTENTION
!
DATA
VALUE/DESCRIPTION
Location
Venice, Italy
Sliding gate length
5mt
Gate weight
1000kg
Moving time
1 minute
Pause time
30 seconds
Nc (Cycles/day)
48
Daily NLS activated
12 hours (LIGHT INTENSITY default= 3)
Battery capacity
18Ah
Daily consumption= A+B+W+NLS
KEY AUTOMATION control units allow to read actual current draw
of motors during work cycle, see relative instruction.