2.1 Connection of the
VOLTAGE LINE
12
Here are the connections for the inputs
11, 12,13
and the setting
up of the terminal board
8,9 and 10.
R
S
T
11
13
12
R
S
T
11
13
12
F
N
8
9
10
8
9
10
8
9
10
400 Vac THREE-PHASE
230 Vac THREE-PHASE
230 Vac SINGLE-PHASE
2.2 Connection of the
MOTOR
1
3
2
U
V
W
THREE-PHASE MOTOR
1
3
2
common
open
close
SINGLE-PHASE MOTOR
The control unit power supply line must always be protected
with a magnetothermal switch or a pair of 5A fuses. A differential
switch is recommended but not indispensable if one is already
installed on the plant.
Pay particular attention not to invert the OPEN and CLOSE
poles. When in doubt as to the correct connection, if possible,
manually position the automation at the midpoint of its stroke.
2.3 Connection of the
SIGNAL LIGHT
15 16
Signal light with electronic card
15 16
6 7
Signal light without card
You can see how to connect a 230V signal light with electronic card or 230V signal light without card.
If is necessary put in
OFF DIP4
as shown in the picture:
2 3 4 5 6
WARNING
This connection cannot be done if you need
to connect a mechanic brake.
Par. 2.4
2
Electrical connections
.
CLOSE
command
Control board dispose of
2 buttons for opening and
closing of the door.
OPEN
command
Be ready to stop the system using the STOP control! To
be sure that the opening is really “opening”, try to block
the photocells: if the gate begins to close, the connec
-
tion is incorrect and the motor OPEN and CLOSE wires
must be inverted.