21
EN
2.11 Connection of
TURNING ON
17 18 19 20 21 22 23 24 26
COM
COM
The buttons for the turning on of the control unit should
be normally open. If more devices are available the
should be serial connected.
In the paragraph 3.1 are described the different fun
-
ctions of each control.
Terminal:
21
OPEN
22
CLOSE
23
START
24
PEDESTRIAN
2.12 Connection of the TIMER
17 18 19 20 21 22 23 24 26
COM
COM
If you need a timer it is possible to connect it to the ter
-
minal board no. 21 and COM. The contact of the timer
is normally open and it should be closed for all the time
that the gate is open.
If an opening command is con-
nected to terminal 21, it must be
connected in parallel.
2.13 Connection of the LIGHT
24 V
24 V
COM
9 11
LIGHT 24 Vac
LIGHT 230 Vac
24 V
24 V
COM
6 7
If you prevue to use the photo-
test or the signal light, you cannot
use this connection.