![Key Automation BOXLED Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/key-automation/boxled/boxled_instructions-and-warnings-for-installation-and-use_1960066007.webp)
EXCLUSION TWILIGHT FUNCTION ON AN OUTPUT
With this programming you can exclude twilight function on the desired ou
-
tput. Excluding the twilight function, the output will only work via radio con
-
trol or via the input on the control unit.
PH. DESCRIPTION
EXAMPLE
1
Press and release the MENU button for a
specific number of times of the output that
you want to turn off twilight function:
6 times output 1,
7 times output 2,
8 times output 3,
9 times output 4,
+ + +
2
The D1 LED performs a number of flashes
corresponding to the number of presses car
-
ried out with a pause of 1 second between
flashes.
+ + +
3
Press and hold the MENU button for more
than 3 seconds
>3s
4
The LED remains OFF
5
Release the MENU button
6
The LED will start emitting 2 slow flashes.
Press the MENU button during the flash of
the desired function
1st flash twilight function OFF
2nd flash twilight function ON
+
7
After pushing MENU botton, The D1 LED
will perform 4 fast flashes
x4
TEMPORARY EXCLUSION TWILIGHT FUNCTION OF AN OUTPUT
To temporarily exclude twilight sensor function on an output, activate the
input corresponding to the output to be excluded for more than 35 seconds.
At this point, the output will be switched off as long as the input is active.
Once the input is no longer activated the output will resume normal opera-
tion.
EN
ERROR MESSAGES
2 rapid flashes on led D1+ PAUSE = overload on output 1
3 rapid flashes on led D1+ PAUSE = overload on output 2
4 rapid flashes on led D1+ PAUSE = overload on output 3
5 rapid flashes on led D1+ PAUSE = overload on output 4
6 quick flashes of LED D1 + pause = OVERHEATING
To reset the error, disconnect the power supply to the control unit.
5 - TESTING AND COMMISSIONING
The system may be put into operation after testing by a qualified technician,
who must perform the tests required by the relevant standards in relation
to the risks present, to check that the installation complies with the relevant
regulatory requirements.