ERROR TYPE
(Warning
, Blocking,
Lockout)
DESCRIPTION
ERROR
CODE
(
OpenTherm)
REFER TO SECTION...
SYSTEM (FLAME, FAN, HYDRAULIC, ETC.) - CONTINUED
B
PWM pump dry run error (feedback 80%)
71
4
B
Warning code from pump (feedback 75%)
72
4
W
VariCAN Error
73
Check Bus
B
Safety Interlock Function activated (controlled shutdown)
74
Info
L
Air Pressure Switch error
75
n/a
W
Air Pressure Switch warning (restart)
76
n/a
B
High water pressure
77
n/a
B/L
Min water flow rate
78
n/a
W
Maximum water flow rate exceeded
79
n/a
W
Quartz crystal error
80
contact service provider
B
0-10V Input out of range
81
Info
INTERNAL SYSTEM
L
Retails supervision error (COM-, Valve-Retails)
93
Reset, contact service if repeated
L
Request for re-update
94
contact service provider
B
Blocking due to programming mode
95
contact service provider
L
Lockout parameter mismatch
96
contact service provider
L
Lockout parameter set
97
contact service provider
B/L
Internal blocking error
98
contact service provider
L
System lockout (internal lockout error)
99
contact service provider
5.2 FAULT FINDING MENU - CONTINUED
67
Installation & Servicing
SECTION 5 - FAULT FINDING
F
AUL
T FINDING F
AUL
T FINDING F
AUL
T FINDING F
AUL
T FINDING F
AUL
T FINDING F
AUL
T FINDING