ERP DATA
MODEL
SYMBOL
UNITS
45
55
45P
55P
Condensing Boiler
n/a
n/a
yes
yes
yes
yes
Low Temperature Boiler
n/a
n/a
no
no
no
no
B1 Boiler
n/a
n/a
no
no
no
no
Cogeneration Space Heater
n/a
n/a
no
no
no
no
Equipped with a Supplementary Heater
n/a
n/a
no
no
no
no
Combination Heater
n/a
n/a
no
no
no
no
Nominal Heat Output for Space Heating
Full Load
P
4
kW
45
55
45
55
Part Load
P
1
kW
14.6
18
14.6
18
Auxiliary Electricity Consumption
Full Load
el
max
kW
0.135
0.128
0.113
0.130
Part Load
el
min
kW
0.03
0.026
0.026
0.024
Standby
P
SB
kW
0.009
0.009
0.002
0.002
Seasonal Space Heating Energy Efficiency
Full Load
ƞ
4
%
88.7
89.5
88.7
89.5
Part Load
ƞ
1
%
97.7
98.5
97.7
98.5
Standby Loss
P
stby
kW
0.08
0.11
0.073
0.082
Ignition
P
ign
kW
0
0
0
0
Emissions
NO
x
mg/kWh
28.5
35.4
43.1
48.4
Annual Energy Consumption
Q
HE
GJ
139
170
137
167
Sound Power Level, Indoors
L
WA
dB
60.6
60.6
64.2
64.2