Product description
37 / 180
016-023
Installation in the concrete slab
Note: With the product variant Staufix Control a remote signal generator is recommended,
since the optical and visual alarm signal can be impaired by the cover on the upper
section <9>.
Ill. [5]
2 Drain body, with (optional*, see Ill. [4]):
1.1
Backwater flap **
1.2
2. Backwater flap
1.3
Emergency closure lever
1.4
Control unit
3
Seat for upper section or extension section, connected to drain body
4 Documents (installation instructions, Declaration of Conformity,
operating instructions for the accessory parts)
5
Screwed sealing plug (functional check emergency closure, seIll. [4])
6
Spigot*
7
Socket*
8
Extension section (option, several if necessary)
9
Upper section with cover**
* pre-assembled ** various model types