23 /88
2019/08
010-296
3.4
Mounting the direct disposal pipe
Only for conversion to system type Direct
For optimum sealing, do not deburr the drilling edges.
• Screw fastening clamps onto the retainers on the tank
.
• Make drillhole in the tapping area (hole saw, Ø 121 mm)
.
• Insert the passage seal into the drillhole.
• Insert the direct disposal pipe into the passage seal and mount the
fastening clamps.
• Connect fabric hose with 2 pipe clamps and 10 Nm torque
onto PE pipe DN 70 with bead.
If connecting to a steel pipe, ensure a restrained
joint.
3.5
Initial filling and leak test
• Perform leak test, to do so:
• Open both service access covers. If the service access covers are
difficult to open, insert a flat screw driver in the groove and lever open
carefully.
• Make sure that there are no external materials or soiling in the grease
separator.
• Use suitable means to close off the outlet and inlet.
• Fill grease separator completely with water and make sure that there
are no leaks.
• Restore functional capability of the outlet and inlet.
The system is now ready for use.
Fig. [3]
3x
3x
Fig. [4]
Содержание EasyClean free
Страница 2: ......
Страница 72: ...72 88 2019 08 010 296...
Страница 87: ...87 88 2019 08 010 296...
Страница 88: ......