25 /88
2019/08
010-296
4.1
Emptying the system type Standard
• Open service access cover.
• Empty tank (extraction).
• If the level in the tank has been lowered to approx. 1/3, open hot water inlet.
• When the tank is completely empty, remove the extraction hose of the disposal vehicle and switch off the hot water
inlet.
• Clean the tank (spray out).
If the tank is not filled with water again after emptying (bypass level), grease and suspended matter can flow freely into
the sewer system.
• Fill the tank up to the bypass.
• Close the service access cover.
4.2
Emptying the system type Direct
• Open service access cover.
• Connect the extraction hose of the disposal vehicle to the direct disposal pipe.
• Empty tank (extraction).
• If the level in the tank has been lowered to approx. 1/3, open hot water inlet.
• When the tank is completely empty, remove the extraction hose from the disposal vehicle and switch the hot water
supply off.
• Clean the tank (spray out).
If the tank is not filled with water again after emptying (bypass level), grease and suspended matter can flow freely into
the sewer system.
• Fill the tank up to the bypass.
• Close the service access cover.