EN
3
Technical data
Technical data of the pumps
Information /
pump type
GTF 600
GTF 1250
Weight
6 kg
10 kg
Power P1 / P2
650W / 400 W
1.3 kW / 0.8 kW
Speed
2750 rpm
2700 rpm
Operating voltage
230 V; 50 Hz
230 V; 50 Hz
Nominal cur-
rent (per pump)
2.9 A
5.4 A
Max. pump-
ing capacity
12 m³/h
20 m³/h
Max. pump-
ing height
8 m
10 m
Max. temperature
Pumped medium
35°C
35°C
Protection rating
IP68 (3m)
IP68 (3m)
Protection class
I
I
Operating mode
S1
S3 (50%)
Motor protection
integrated
integrated
Recom-
mended fuse
(Mono)
Recommended
fuse (Duo)
C16 A
C16 A
C16 A
C16 A
Residual current
device (RCD)
30 mA
30 mA
Fig. 1: Pumping capacity diagram
Tank
Data
Values
Duo weight
30-40 kg depend-
ing on the pump type
Inlet
DN 100/150
Pressure pipe connection
DN 40/50
Ventilation
DN 50/70
Pumping volume
Aqualift 100 tronic,
Aqualift 200 tronic
50l
100l
28 / 132