17
Menu navigation
The switchgear menu navigation is divided into the sy-
stem information and also three separate main menu
items. The background lighting is activated by pressing
the operating key once.
OK-key
Jumps to the next lower level
ESC-key:
Jumps to the next higher level
▲
: Navigation within a level
▼
The acoustic signal can be acknowledged
by pressing once.
If the error has been rectified, the alarm
key can be pressed again to acknowledge
the optical error.
If the error has not been rectified, pressing the alarm key
again will retrigger the acoustic alarm.
If there is a mains power failure, the system is not opera-
tional. The switchgear goes into stand-by mode (battery
mode). This is signalised by an acoustic and optical alarm
The acoustic alarm can be acknowledged by pressing the
alarm key. The stand-by mode is maintained for at least
72 hours. If the battery is discharged, the device auto-
matically switches off. The switchgear can be switched
off manually by pressing the alarm key (for more than 5
sec) in stand-by mode.
When the mains power comes on again, the device in-
itialises automatically and is operational again.
Note:
Some menus are protected by a password to ensure the
system is used properly.
6. Commissioning
6.4.1 System menu
Informationen
Wartung
Einstellungen
0.
Systeminfo
Leistungsgröße
Sensorkonfiguration
Datum
Uhrzeit
Füllstandsanzeige
Fehler/Ereignisse
Beispiel:
Füllstand:
Display the hierarchy level incl.
Numbering
System type
Control type
Date / time
Current filling level
>
Floater:
Pump:
Information
Maintenance
Positions
Содержание Aqualift F Duo/XXL SPF 260 KE