UBS Hydro II
Safety
EN
2018-05-02
20 / 60
WARNING
Risk of injury / risk damage to environment due to poor / missing
maintenance!
There is a risk of injury, as well as a risk of damage to environment and material
damages (on the machine or the system) due to poor maintenance!
•
Only perform maintenance and cleaning works when the engine stands
still.
•
When working on the engine, generally pull the spark plugs off.
•
The operating personnel are allowed to perform simple cleaning and
adjusting works. Maintenance and service works are only allowed to be
done by instructed specialist personnel
.
•
Observe the instructions given in the original Operating Instructions of the
subcontracted parts.
•
If safeguards and tools are subject to wearing, they have to be checked
regularly and replaced, if necessary.
•
For the replacement of cutting tools use the appropriate tool and suitable
protective equipment.
•
After maintenance and cleaning works, it is definitely necessary to remount
the safeguards and to place them in their protecting position!
•
Only use original spare parts from the manufacturer because these meet
the technical specifications and with this, the risk of accidents will be
minimised!
•
Cleaning works with the high-pressure cleaner should be done in a way
that the water jet does not directly meet the bearing, rotating parts,
lubricating nipples, shaft sealing rings, wheel hubs, etc. After each cleaning
procedure with the high pressure cleaner, the lubricating points must be re-
greased. If this is not observed, the warranty claim will be rendered null
and void!
•
After 5 operating hours and then regularly, check the screws and nuts for
tight fit and retighten them, if necessary.
•
After maintenance mount the safeguards and place them in their protecting
position.
•
If the machine is maintained, cleaned, or repaired in a raised position,
always secure it by suitable supporting elements.
When working on the electrical system, the earth strap must be removed from the
battery.
•
If welding works are done on the machine, disconnect the battery.
•
Repair works like welding, drilling, grinding, etc. may not be done on load-
bearing, safety-related parts.
•
Before starting any repair works, make sure that the hydraulic system has
been depressurised, because pressurised fluids can penetrate skin and
cause serious injuries! Therefore, immediately consult a doctor - risk of
infection!
•
Check hydraulic connections after 5 operating hours for the first time,
retighten if necessary!
Only re-tightening is not successful!
First release a leaky hydraulic screwed connection, then move hose or screwed
connection. After that, the screwed connection can be tightened again.