15 

OSF-4-BA-e-1510

 

5.7  Lighting control 

All  microscopes  in  the  OSF-4  series  have 

simple  reflected  and  transmitted  light 

illumination

With  the  mains  cable  connected  you  can  switch  the  light  units  on and  off  using  the 
switches  on  the  stand  base  as  follows:  for 

reflected  light 

use  the 

switch  on  the 

right rear corner

 and for 

transmitted light use the switch on the left rear corner

The light intensity cannot be adjusted. 

5.8  Using external illumination units 

If, when using a microscope in its standard version, the lighting is not suitable for the 
application, then it often makes sense to fit an external lighting unit to overcome this 
problem. 

The lighting units which are suitable for devices of the OSF-4 series, are goose neck 
lighting units 

(see figure)

. These are available as LED as well as halogen versions 

and also have an on/off switch or different controller. 

Typical goose neck lighting unit 

Using goose neck lighting units 

Depending on the requirements, a goose neck lighting unit is placed next to, in front 
of or behind the microscope. The light source is in the housing of the unit and is 
emitted through one or several optical fibre cables.  
These cables are flexible and therefore offer a large number of positioning options, 
so that the object being observed is perfectly illuminated. 

Содержание OSF-4

Страница 1: ...mbH Ziegelei 1 D 72336 Balingen E mail info kern sohn com Tel 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com User instructions Stereo microscope KERN OSF 4 OSF 430 OSF 431 OSF 434...

Страница 2: ......

Страница 3: ...ssembly 9 5 Operation and functionality 11 5 1 Getting started 11 5 2 Adjusting the interpupillary distance 11 5 3 Adjusting the magnification 11 5 4 Dioptre adjustment and focussing 12 5 5 Adjusting...

Страница 4: ...o the electrical parts in the base of the device must not be tampered with as in this area there is an additional risk of triggering an electric shock 1 2 Notes on the electrical system Before connect...

Страница 5: ...older must not be rotated back too far If you do this there is a risk that the microscope could tip over When the microscope is not being used you should fit the objective cap and cover the microscope...

Страница 6: ...these are highly flammable substances You must therefore keep it away from naked flames and electrical devices which can be switched on and off and only use it in well ventilated rooms However organi...

Страница 7: ...OSF 4 BA e 1510 6 2 Nomenclature Using the OSF 430 as an example...

Страница 8: ...7 OSF 4 BA e 1510 Special features of OSF 434 OSF 435 The focus dial has a coarse adjustment knob and a fine adjustment knob...

Страница 9: ...d of view mm Objective Stand Illumination OSF 430 Binocular WF 10x 20 mm 20 1x 3x mechanical 1W LED reflected light 0 21W LED transmitted light OSF 431 Binocular WF 10x 20 mm 20 2x 4x mechanical 1W LE...

Страница 10: ...epieces are already fitted in the tube You just need to remove the protective film which covers them When doing this make sure that you do not touch the optical lenses with your fingers In general you...

Страница 11: ...OSF 4 BA e 1510 10 Assembled stereo microscope...

Страница 12: ...e the gap between the two eyepieces must be re adjusted While you are looking through the eyepieces use one hand to hold the righthand or lefthand prism housing firmly By rotating outwards or inwards...

Страница 13: ...k through the righthand eyepiece without dioptre adjustment ring with the right eye and bring the object into focus by using the focus control dials 4 Now set the largest magnification 5 Once again st...

Страница 14: ...ng observed should collide Torque of the focus wheels OSF 434 OSF 435 You can adjust the torque of the focus wheels by turning the ring which is fitted along the axis of the lefthand focus wheel in a...

Страница 15: ...ed by the glasses symbol on the side They are also marked in the item description by an additional H example HSWF 10x 23 mm When fitting the eye cups make sure that the dioptre setting is not moved We...

Страница 16: ...application then it often makes sense to fit an external lighting unit to overcome this problem The lighting units which are suitable for devices of the OSF 4 series are goose neck lighting units see...

Страница 17: ...7 Features Model outfit Kern model Order number OSF 430 OSF 431 OSF 434 OSF 435 Eyepieces WF 5x 16 2 mm OZB A4101 WF 10x 20 mm OZB A4102 WF 15x 15 mm OZB A4103 WF 20x 10 mm OZB A4104 Stand mechanical...

Страница 18: ...ufficient The wrong bulb has been used The input voltage is too low Optical unit Problem Possible causes You can see two images The interpupillary distance is not set correctly The magnifications of t...

Страница 19: ...materials which you can dispose of at your local recycling centre Disposal of the storage box and device must be carried out by the operator in accordance with all national or regional laws in force...

Отзывы: